Search
×
FR

Placeholder headline

This is just a placeholder headline

API MPMS CH 10.8, 3rd Edition: Standard Test Method for Sediment in Crude Oil by Membrane Filtration

$

114

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO/TR 42505:2026 Sharing economy — Shared manufacturing — Concepts and models

$

192

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 4306-1:2026 Cranes — Vocabulary — Part 1: General

$

436

BUY NOW

ISO 21978:2023

ISO 21978:2023 Air to water heat pumps – Testing and rating at part load conditions and calculation of seasonal coefficient of performance for space heating

CDN $352.00

SKU: 2136e38d2c02 Categories: ,

Description

This document specifies test conditions for determining the seasonal performance characteristics of air to water heat pumps for space heating with electrically driven compressors with or without supplementary heater. In the case of air to water heat pumps for space heating consisting of several parts with refrigerant or water connections, this document applies only to those designed and supplied as a complete package.

The seasonal coefficient of performance depends, inter alia, on the climate conditions and temperature regime of the space heating distribution network.

This document specifies:

     three design conditions, each of them being characterized by a design temperature which represents the lowest temperature that can occur in that design condition;

     three water temperature distribution regimes, namely “temperature application” in the text.

This document also provides a full description of three heating seasons that can be used with the associated design conditions.

Edition

2

Published Date

2023-12-01

Status

PUBLISHED

Pages

50

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies test conditions for determining the seasonal performance characteristics of air to water heat pumps for space heating with electrically driven compressors with or without supplementary heater. In the case of air to water heat pumps for space heating consisting of several parts with refrigerant or water connections, this document applies only to those designed and supplied as a complete package.

The seasonal coefficient of performance depends, inter alia, on the climate conditions and temperature regime of the space heating distribution network.

This document specifies:

-     three design conditions, each of them being characterized by a design temperature which represents the lowest temperature that can occur in that design condition;

-     three water temperature distribution regimes, namely “temperature application” in the text.

This document also provides a full description of three heating seasons that can be used with the associated design conditions.

Previous Editions

Can’t find what you are looking for?

Please contact us at: