ISO 22515:2021
ISO 22515:2021 Water quality – Iron-55 – Test method using liquid scintillation counting
CDN $233.00
Description
This document specifies a test method for the determination of iron-55 (55Fe) activity concentration in samples of all types of water using liquid scintillation counting (LSC). Using currently available liquid scintillation counters, this test method can measure the 55Fe activity concentrations in the range from the limit of detection up to 120 mBq l-1. These values can be achieved with a counting time between 7 200 s and 10 800 s for a sample volume from 0,5 l to 1,5 l. Higher activity concentrations can be measured by either diluting the sample or using smaller sample aliquots or both.
NOTE     These performance indicators are wholly dependent on the measurement regimes in individual laboratories; in particular, the detection limits are influenced by amount of stable iron present.
The range of application depends on the amount of dissolved material in the water and on the performance characteristics of the measurement equipment (background count rate and counting efficiency).
It is the laboratory’s responsibility to ensure the suitability of this test method for the water samples tested.
Edition
1
Published Date
2021-05-21
Status
PUBLISHED
Pages
20
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document specifies a test method for the determination of iron-55 (55Fe) activity concentration in samples of all types of water using liquid scintillation counting (LSC). Using currently available liquid scintillation counters, this test method can measure the 55Fe activity concentrations in the range from the limit of detection up to 120 mBq l-1. These values can be achieved with a counting time between 7 200 s and 10 800 s for a sample volume from 0,5 l to 1,5 l. Higher activity concentrations can be measured by either diluting the sample or using smaller sample aliquots or both.
NOTE     These performance indicators are wholly dependent on the measurement regimes in individual laboratories; in particular, the detection limits are influenced by amount of stable iron present.
The range of application depends on the amount of dissolved material in the water and on the performance characteristics of the measurement equipment (background count rate and counting efficiency).
It is the laboratory’s responsibility to ensure the suitability of this test method for the water samples tested.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 11665:2020 Measurement of radioactivity in the environment – Air: radon-222 – Part 3: Spot measurement method of the potential alpha energy concentration of its short-lived decay products
CDN $233.00 Add to cart -

ISO 51940:2022 Guidance for dosimetry for sterile insects release programs
CDN $115.00 Add to cart -

ISO 13165:2024 Water quality – Radium-226 – Part 3: Test method using coprecipitation and gamma-ray spectrometry
CDN $173.00 Add to cart -

ISO 11665:2019 Measurement of radioactivity in the environment – Air: radon-222 – Part 8: Methodologies for initial and additional investigations in buildings
CDN $233.00 Add to cart