REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API SPEC 14L: Lock Mandrels and Landing Nipples : Reaffirmed

$

273

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 20F: Corrosion Resistant Bolting for Use in the Petroleum and Natural Gas Industries : Reaffirmed

$

169

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 5NCL Nickel Content Limits for API 5CT Sour Service Products

$

149

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 19ICD: Inflow Control Devices : Reaffirmed

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 23.2: Reconciliation of Liquid Tank Car(s) Quantities : Reaffirmed

$

218

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 16A: Specification for Drill-through Equipment

$

322

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-2: Field Testing Oil-based Drilling Fluids wA1

$

388

BUY NOW

ISO 2268:1972

ISO 2268:1972 Surface active agents (non-ionic) – Determination of polyethylene glycols and non-ionic active matter (adducts) – Weibull method

CDN $76.00

SKU: 23c39a1cfb75 Category:

Description

The method relies on the facts that both non-ionic adducts and polyethylene glycols are soluble in sodium chloride solution, but one is soluble in ethyl acetate whereas the other is not. Separation of the polyethylene glycols and the adducts is, therefore, possible by the following methods: Dissolution of the sample in ethyl acetate and extraction of polyethylene glycols by sodium chloride solution. Extraction of the polyethylene glycols isolated in the sodium chloride solution with chloroform, removal of the solvent and weighing of the residue. Evaporation of the ethyl acetate solution which contains the adducts and weighing of the residue.

Edition

1

Published Date

1972-11-01

Status

PUBLISHED

Pages

5

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

The method relies on the facts that both non-ionic adducts and polyethylene glycols are soluble in sodium chloride solution, but one is soluble in ethyl acetate whereas the other is not. Separation of the polyethylene glycols and the adducts is, therefore, possible by the following methods: Dissolution of the sample in ethyl acetate and extraction of polyethylene glycols by sodium chloride solution. Extraction of the polyethylene glycols isolated in the sodium chloride solution with chloroform, removal of the solvent and weighing of the residue. Evaporation of the ethyl acetate solution which contains the adducts and weighing of the residue.

Previous Editions

Can’t find what you are looking for?

Please contact us at: