ISO 22930:2020
ISO 22930:2020 Evaluating the performance of continuous air monitors – Part 2: Air monitors based on flow-through sampling techniques without accumulation
CDN $310.00
Description
The use of a continuous air monitor (CAM) is mainly motivated by the need to be alerted quickly and in the most accurate way possible with an acceptable false alarm rate when significant activity concentration value is exceeded, in order to take appropriate measures to reduce exposure of those involved.
The performance of this CAM does not only depend on the metrological aspect characterized by the decision threshold, the limit of detection and the measurement uncertainties but also on its dynamic capacity characterized by its response time as well as on the minimum detectable activity concentration corresponding to an acceptable false alarm rate.
The ideal performance is to have a minimum detectable activity concentration as low as possible associated with a very short response time, but unfortunately these two criteria are in opposition. It is therefore important that the CAM and the choice of the adjustment parameters and the alarm levels be in line with the radiation protection objectives.
This document describes
– the dynamic behaviour and the determination of the response time,
– the determination of the characteristic limits (decision threshold, detection limit, limits of the coverage interval), and
– a possible way to determine the minimum detectable activity concentration and the alarms setup.
Finally the annexes of this document show actual examples of CAM data which illustrate how to quantify the CAM performance by determining the response time, the characteristics limits, the minimum detectable activity concentration and the alarms setup.
Edition
1
Published Date
2020-05-07
Status
PUBLISHED
Pages
32
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
The use of a continuous air monitor (CAM) is mainly motivated by the need to be alerted quickly and in the most accurate way possible with an acceptable false alarm rate when significant activity concentration value is exceeded, in order to take appropriate measures to reduce exposure of those involved.
The performance of this CAM does not only depend on the metrological aspect characterized by the decision threshold, the limit of detection and the measurement uncertainties but also on its dynamic capacity characterized by its response time as well as on the minimum detectable activity concentration corresponding to an acceptable false alarm rate.
The ideal performance is to have a minimum detectable activity concentration as low as possible associated with a very short response time, but unfortunately these two criteria are in opposition. It is therefore important that the CAM and the choice of the adjustment parameters and the alarm levels be in line with the radiation protection objectives.
This document describes
- the dynamic behaviour and the determination of the response time,
- the determination of the characteristic limits (decision threshold, detection limit, limits of the coverage interval), and
- a possible way to determine the minimum detectable activity concentration and the alarms setup.
Finally the annexes of this document show actual examples of CAM data which illustrate how to quantify the CAM performance by determining the response time, the characteristics limits, the minimum detectable activity concentration and the alarms setup.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 9698:2019 Water quality – Tritium – Test method using liquid scintillation counting
CDN $263.00 Add to cart -

ISO 28077:2024 Photocarcinogenesis action spectrum (non-melanoma skin cancers)
CDN $131.00 Add to cart -

ISO 22127:2019 Dosimetry with radiophotoluminescent glass dosimeters for dosimetry audit in MV X-ray radiotherapy
CDN $195.00 Add to cart -

ISO 21482:2007 Ionizing-radiation warning – Supplementary symbol
CDN $195.00 Add to cart