ISO 23369:2022

ISO 23369:2022 Hydraulic fluid power – Multi-pass method of evaluating filtration performance of a filter element under cyclic flow conditions

CDN $310.00

SKU: cccd33ad2164 Categories: ,

Description

This document specifies:

a)    A multi-pass filtration performance test under cyclic flow conditions with continuous contaminant injection for hydraulic fluid power filter elements.

b)    A procedure for determining the contaminant capacity, particulate removal and differential pressure characteristics.

c)    A test currently applicable to hydraulic fluid power filter elements that exhibit an average filtration ratio greater than or equal to 75 for particle sizes ≤25 µm(c), and a final test system reservoir gravimetric level of less than 200 mg/L. It is necessary to determine by validation the range of flow rates and the lower particle size limit that can be used in test facilities.

d)    A test using ISO 12103‑1 A3 medium test dust contaminant and a test fluid.

This document provides a test procedure that yields reproducible test data for appraising the filtration performance of a hydraulic fluid power filter element without influence of electrostatic charge.

This document is applicable to three test conditions:

    Base upstream gravimetric level of 3 mg/L;

    Base upstream gravimetric level of 10 mg/L;

    Base upstream gravimetric level of 15 mg/L.

Edition

2

Published Date

2022-12-19

Status

PUBLISHED

Pages

35

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies:

a)    A multi-pass filtration performance test under cyclic flow conditions with continuous contaminant injection for hydraulic fluid power filter elements.

b)    A procedure for determining the contaminant capacity, particulate removal and differential pressure characteristics.

c)    A test currently applicable to hydraulic fluid power filter elements that exhibit an average filtration ratio greater than or equal to 75 for particle sizes ≤25 µm(c), and a final test system reservoir gravimetric level of less than 200 mg/L. It is necessary to determine by validation the range of flow rates and the lower particle size limit that can be used in test facilities.

d)    A test using ISO 12103‑1 A3 medium test dust contaminant and a test fluid.

This document provides a test procedure that yields reproducible test data for appraising the filtration performance of a hydraulic fluid power filter element without influence of electrostatic charge.

This document is applicable to three test conditions:

-    Base upstream gravimetric level of 3 mg/L;

-    Base upstream gravimetric level of 10 mg/L;

-    Base upstream gravimetric level of 15 mg/L.