Search
×
FR

Placeholder headline

This is just a placeholder headline

API MPMS CH 10.8, 3rd Edition: Standard Test Method for Sediment in Crude Oil by Membrane Filtration

$

114

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO/TR 42505:2026 Sharing economy — Shared manufacturing — Concepts and models

$

192

BUY NOW

Placeholder headline

This is just a placeholder headline

ISO 4306-1:2026 Cranes — Vocabulary — Part 1: General

$

436

BUY NOW

ISO 23443:2020

ISO 23443:2020 Infant formula and adult nutritionals – Determination of Œ≤-carotene, lycopene and lutein by reversed-phase ultra-high performance liquid chromatography (RP-UHPLC)

CDN $310.00

SKU: 50d85edf2576 Category:

Description

This document specifies a method for the quantitative determination of β-carotene and lycopene in infant formula and adult nutritionals in solid (i.e. powders) or liquid (i.e. ready-to-feed liquids and liquid concentrates) forms using reversed-phase ultra-high performance liquid chromatography (RP-UHPLC) and UV-visible detection. The application range runs from 1 μg/100 g to 1 500 μg/100 g for lycopene and from 1 μg/100 g to 2 250 μg/100 g for β-carotene. Based on the single-laboratory validation, the limit of detection (LOD) was 0,1 μg/100 g and the limit of quantification (LOQ) was 0,3 μg/100 g for each carotenoid.

The method does not apply to materials that contain measurable levels of β-apo-8′-carotenal. The reproducibility data meets the requirements given in References [8] and [10].

Annex C specifies the determination of lutein. The reproducibility data does not meet the requirements given in Reference [9].

Edition

1

Published Date

2020-07-02

Status

PUBLISHED

Pages

32

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies a method for the quantitative determination of β-carotene and lycopene in infant formula and adult nutritionals in solid (i.e. powders) or liquid (i.e. ready-to-feed liquids and liquid concentrates) forms using reversed-phase ultra-high performance liquid chromatography (RP-UHPLC) and UV-visible detection. The application range runs from 1 μg/100 g to 1 500 μg/100 g for lycopene and from 1 μg/100 g to 2 250 μg/100 g for β-carotene. Based on the single-laboratory validation, the limit of detection (LOD) was 0,1 μg/100 g and the limit of quantification (LOQ) was 0,3 μg/100 g for each carotenoid.

The method does not apply to materials that contain measurable levels of β-apo-8′-carotenal. The reproducibility data meets the requirements given in References [8] and [10].

Annex C specifies the determination of lutein. The reproducibility data does not meet the requirements given in Reference [9].

Previous Editions

Can’t find what you are looking for?

Please contact us at: