ISO 23581:2024
ISO 23581:2024 Petroleum products and related products – Determination of kinematic viscosity – Method by Stabinger type viscometer
CDN $186.00
Description
This document specifies a procedure for the determination of kinematic viscosity, ν, by calculation from dynamic viscosity, η, and density, ρ, of both transparent and opaque liquid petroleum products and crude oils using the Stabinger type viscometer.
The result obtained using the procedure described in this document depends on the rheological behaviour of the sample. This document is predominantly applicable to liquids whose shear stress and shear rate are proportional (Newtonian flow behaviour). If the viscosity changes significantly with the shear rate, comparison with other measuring methods is not possible except at similar shear rates.
The precision has been determined only for the materials, density ranges and temperatures described in Clause 13. The test method can be applied to a wider range of viscosity, density, temperature and materials. It is possible that the precision and bias are applicable for materials which are not listed in Clause 13.
Edition
2
Published Date
2024-05-14
Status
PUBLISHED
Pages
18
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document specifies a procedure for the determination of kinematic viscosity, ν, by calculation from dynamic viscosity, η, and density, ρ, of both transparent and opaque liquid petroleum products and crude oils using the Stabinger type viscometer.
The result obtained using the procedure described in this document depends on the rheological behaviour of the sample. This document is predominantly applicable to liquids whose shear stress and shear rate are proportional (Newtonian flow behaviour). If the viscosity changes significantly with the shear rate, comparison with other measuring methods is not possible except at similar shear rates.
The precision has been determined only for the materials, density ranges and temperatures described in Clause 13. The test method can be applied to a wider range of viscosity, density, temperature and materials. It is possible that the precision and bias are applicable for materials which are not listed in Clause 13.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 15081:2011 Agricultural equipment – Graphical symbols for pressurized irrigation systems
CDN $124.00 Add to cart -

ISO 21637:2020 Solid recovered fuels – Vocabulary
CDN $82.00 Add to cart -

ISO 18115:2023 Surface chemical analysis – Vocabulary – Part 1: General terms and terms used in spectroscopy
CDN $82.00 Add to cart -

ISO 55000:2024 Asset management – Vocabulary, overview and principles
CDN $251.00 Add to cart