Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 24631:2012

ISO 24631:2012 Radiofrequency identification of animals – Part 7: Synchronization of ISO 11785 identification systems

CDN $186.00

Description

ISO 24631-7:2012 specifies rules and procedures for synchronizing RFID transceivers while reading transponders used in individual animal identification complying to ISO 11784 and ISO 11785.

The synchronization scheme described herein may be fully implemented within each reader, and such readers when attached to the synchronization bus create a peer-to-peer network (all readers are equal ? there is no dedicated master). Additionally, a cluster of readers, which could be in a master/slave configuration, may also be added to the bus using a dedicated, manufacturer specific Synchronization Interface. The Synchronization Interface presents to the synchronization bus electrical characteristics identical to those of a single peer-to-peer reader.

The transceiver conformance standard ISO 24631-2 permits activation on/off timing tolerances of ‚àí0/+1 ms and therefore gives reader manufacturers options as to their preferred method for detecting the HDX header; partial or full. However, when synchronizing readers, irrespective of which header detection method is used, it is critical that all readers adhere strictly to the specific timings and timing tolerances as given in the timing diagrams.

Particular attention should also be given to fault diagnostics which becomes more important when a reader network comprises products from different manufacturers. The obvious case is where a reader which is part of a network has become detached e.g. sync cable break, and it considers it’s self to be now standalone and thus permitted to operate asynchronously to the detriment of all other readers.

Edition

1

Published Date

2012-12-03

Status

PUBLISHED

Pages

17

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 24631-7:2012 specifies rules and procedures for synchronizing RFID transceivers while reading transponders used in individual animal identification complying to ISO 11784 and ISO 11785.

The synchronization scheme described herein may be fully implemented within each reader, and such readers when attached to the synchronization bus create a peer-to-peer network (all readers are equal ? there is no dedicated master). Additionally, a cluster of readers, which could be in a master/slave configuration, may also be added to the bus using a dedicated, manufacturer specific Synchronization Interface. The Synchronization Interface presents to the synchronization bus electrical characteristics identical to those of a single peer-to-peer reader.

The transceiver conformance standard ISO 24631-2 permits activation on/off timing tolerances of ‚àí0/+1 ms and therefore gives reader manufacturers options as to their preferred method for detecting the HDX header; partial or full. However, when synchronizing readers, irrespective of which header detection method is used, it is critical that all readers adhere strictly to the specific timings and timing tolerances as given in the timing diagrams.

Particular attention should also be given to fault diagnostics which becomes more important when a reader network comprises products from different manufacturers. The obvious case is where a reader which is part of a network has become detached e.g. sync cable break, and it considers it's self to be now standalone and thus permitted to operate asynchronously to the detriment of all other readers.

Previous Editions

Can’t find what you are looking for?

Please contact us at: