Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 26802:2010

ISO 26802:2010 Nuclear facilities – Criteria for the design and the operation of containment and ventilation systems for nuclear reactors

CDN $422.00

SKU: 25ab1e21d755 Category:

Description

ISO 26802:2010 specifies the applicable requirements related to the design and the operation of containment and ventilation systems of nuclear power plants and research reactors taking into account the following.

For nuclear power plants, ISO 26802:2010 addresses only reactors that have a secondary confinement system based on IAEA recommendations.

For research reactors, ISO 26802:2010 applies specifically to reactors for which accidental situations can challenge the integrity or leak-tightness of the containment barrier, i.e. in which a high-pressure or -temperature transient can occur and for which the isolation of the containment building and the shut-off of the associated ventilation systems of the containment building is required.

The requirements of ISO 26802:2010 apply to research reactors in which the increase of pressure or temperature during accidental situations do not risk damaging the ventilation systems, although the requirements applicable for the design and the use of ventilation systems are given in ISO 17873.

Edition

1

Published Date

2010-07-15

Status

PUBLISHED

Pages

84

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 26802:2010 specifies the applicable requirements related to the design and the operation of containment and ventilation systems of nuclear power plants and research reactors taking into account the following.

For nuclear power plants, ISO 26802:2010 addresses only reactors that have a secondary confinement system based on IAEA recommendations.

For research reactors, ISO 26802:2010 applies specifically to reactors for which accidental situations can challenge the integrity or leak-tightness of the containment barrier, i.e. in which a high-pressure or -temperature transient can occur and for which the isolation of the containment building and the shut-off of the associated ventilation systems of the containment building is required.

The requirements of ISO 26802:2010 apply to research reactors in which the increase of pressure or temperature during accidental situations do not risk damaging the ventilation systems, although the requirements applicable for the design and the use of ventilation systems are given in ISO 17873.

Previous Editions

Can’t find what you are looking for?

Please contact us at: