ISO 28523:2009
ISO 28523:2009 Ships and marine technology – Lubricating and hydraulic oil systems – Guidance for sampling to determine cleanliness and particle contamination
CDN $124.00
Description
ISO 28523:2009 specifies methods for dynamic and static extraction of fluid samples from lubricating and hydraulic oil systems.
A correct execution of the sampling is essential when analysing fluids from lubricating and hydraulic oil systems.
In order to achieve reliable and comparable analysis results, the sampling must be performed under defined conditions and operating environment.
When the system has reached its operating temperature, a representative sample is extracted from where the fluid is in a turbulent flow condition. This method is called dynamic sampling. If this is not possible, the sample can be extracted from the system tank. This method is called static sampling.
ISO 28523:2009 specifies methods for both dynamic and static sampling in connection with collection in bottles.
For extraction of samples through a filtration kit for comparison with “master slides”, reference is made to the manuals from the suppliers of such equipment.
Edition
1
Published Date
2009-02-09
Status
PUBLISHED
Pages
7
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 28523:2009 specifies methods for dynamic and static extraction of fluid samples from lubricating and hydraulic oil systems.
A correct execution of the sampling is essential when analysing fluids from lubricating and hydraulic oil systems.
In order to achieve reliable and comparable analysis results, the sampling must be performed under defined conditions and operating environment.
When the system has reached its operating temperature, a representative sample is extracted from where the fluid is in a turbulent flow condition. This method is called dynamic sampling. If this is not possible, the sample can be extracted from the system tank. This method is called static sampling.
ISO 28523:2009 specifies methods for both dynamic and static sampling in connection with collection in bottles.
For extraction of samples through a filtration kit for comparison with “master slides”, reference is made to the manuals from the suppliers of such equipment.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 80004:2020 Nanotechnologies – Vocabulary – Part 3: Carbon nano-objects
CDN $82.00 Add to cart -

ISO 22553:2019 Paints and varnishes – Electro-deposition coatings – Part 1: Vocabulary
CDN $82.00 Add to cart -

ISO 80004:2011 Nanotechnologies – Vocabulary – Part 7: Diagnostics and therapeutics for healthcare
CDN $124.00 Add to cart -

ISO 10110:2019 Optics and photonics – Preparation of drawings for optical elements and systems – Part 1: General
CDN $336.00 Add to cart