Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 29341:2011

ISO 29341:2011 Information technology – UPnP Device Architecture – Part 16-1: Low Power Device Control Protocol – Low Power Architecture

CDN $0.00

Description

ISO/IEC 29341-16-1:2011(E) defines an architecture that will address the issue of reporting and tracking power states of nodes in a network. The UPnP Low Power solution is designed to enable nodes in the network to report and track the Low Power states of other nodes in the network. Additionally, for nodes that support wake up capabilities, this architecture addresses methods to wake up those nodes when required. The objective of the UPnP Low Power solution is to allow UPnP devices to conserve energy and still be discoverable by UPnP Control Points. The UPnP Control Point will be aware of the UPnP devices and services implemented on a Low Power device even when the Low Power device is in a power savings mode. This architecture document defines two UPnP services that comprise the UPnP Low Power framework: Low Power device service and Basic Power Management Proxy service.

Edition

1

Published Date

2011-08-30

Status

PUBLISHED

Pages

35

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO/IEC 29341-16-1:2011(E) defines an architecture that will address the issue of reporting and tracking power states of nodes in a network. The UPnP Low Power solution is designed to enable nodes in the network to report and track the Low Power states of other nodes in the network. Additionally, for nodes that support wake up capabilities, this architecture addresses methods to wake up those nodes when required. The objective of the UPnP Low Power solution is to allow UPnP devices to conserve energy and still be discoverable by UPnP Control Points. The UPnP Control Point will be aware of the UPnP devices and services implemented on a Low Power device even when the Low Power device is in a power savings mode. This architecture document defines two UPnP services that comprise the UPnP Low Power framework: Low Power device service and Basic Power Management Proxy service.

Previous Editions

Can’t find what you are looking for?

Please contact us at: