REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 12R1: Installation, Operation, Maintenance, Inspection, and Repair of Tanks in Production Service

$

285

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report 2583 – Measurement of Produced Water for Custody Transfer

$

174

BUY NOW

Placeholder headline

This is just a placeholder headline

API Bulletin 592 – Elements of a Fixed Equipment Mechanical Integrity (FE MI) Program

$

142

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC Q1: Addenda 2

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 2583 : Measurement of Produced Water for Custody Transfer

$

174

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 2581: Wet Gas Sampling

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 2581 Wet Gas Sampling : Errata 1

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API 510: Pressure Vessel Inspection Code: In-service Inspection, Rating, Repair, and Alteration

$

481

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 6AV1: Validation of Safety and Shutdown Valves for Sandy Service : Edition 4

$

208

BUY NOW

ISO 3210:2017

ISO 3210:2017 Anodizing of aluminium and its alloys – Assessment of quality of sealed anodic oxidation coatings by measurement of the loss of mass after immersion in acid solution(s)

CDN $115.00

Description

ISO 3210:2017 specifies methods of assessing the quality of sealed anodic oxidation coatings on aluminium and its alloys by measurement of the loss of mass after immersion in acid solution(s).

It consists of the following two methods.

– Method 1: Assessment of quality of sealed anodic oxidation coatings by measurement of the loss of mass after immersion in a phosphoric acid based solution without prior acid treatment.

– Method 2: Assessment of quality of sealed anodic oxidation coatings by measurement of the loss of mass after immersion in a phosphoric acid based solution with prior acid treatment.

Method 1 is applicable to anodic oxidation coatings intended for decorative or protective purposes or where resistance to staining is important.

Method 2 is applicable to anodic oxidation coatings intended for outdoor architectural purposes. For less severe applications, Method 1 can be more suitable.

The methods are not applicable to the following:

– hard-type anodic oxidation coatings which normally are not sealed;

– anodic oxidation coatings that have been sealed only in dichromate solutions;

– anodic oxidation coatings produced in chromic acid solutions;

– anodic oxidation coatings that have undergone treatment to render them hydrophobic.

NOTE 1 The methods assess the quality of hydrothermal sealing applied to anodized aluminium. They can be appropriate for other sealing methods.

NOTE 2 The methods are destructive and can serve as reference methods in case of doubt or dispute regarding the results of the test for loss of absorptive power (see ISO 2143) or the measurement of admittance (see ISO 2931).

Edition

4

Published Date

2017-10-30

Status

PUBLISHED

Pages

7

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 3210:2017 specifies methods of assessing the quality of sealed anodic oxidation coatings on aluminium and its alloys by measurement of the loss of mass after immersion in acid solution(s).

It consists of the following two methods.

- Method 1: Assessment of quality of sealed anodic oxidation coatings by measurement of the loss of mass after immersion in a phosphoric acid based solution without prior acid treatment.

- Method 2: Assessment of quality of sealed anodic oxidation coatings by measurement of the loss of mass after immersion in a phosphoric acid based solution with prior acid treatment.

Method 1 is applicable to anodic oxidation coatings intended for decorative or protective purposes or where resistance to staining is important.

Method 2 is applicable to anodic oxidation coatings intended for outdoor architectural purposes. For less severe applications, Method 1 can be more suitable.

The methods are not applicable to the following:

- hard-type anodic oxidation coatings which normally are not sealed;

- anodic oxidation coatings that have been sealed only in dichromate solutions;

- anodic oxidation coatings produced in chromic acid solutions;

- anodic oxidation coatings that have undergone treatment to render them hydrophobic.

NOTE 1 The methods assess the quality of hydrothermal sealing applied to anodized aluminium. They can be appropriate for other sealing methods.

NOTE 2 The methods are destructive and can serve as reference methods in case of doubt or dispute regarding the results of the test for loss of absorptive power (see ISO 2143) or the measurement of admittance (see ISO 2931).

Previous Editions

Can’t find what you are looking for?

Please contact us at: