REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API TR 2583 : Measurement of Produced Water for Custody Transfer

$

174

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 2581: Wet Gas Sampling

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 2581 Wet Gas Sampling : Errata 1

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API 510: Pressure Vessel Inspection Code: In-service Inspection, Rating, Repair, and Alteration

$

481

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 6AV1: Validation of Safety and Shutdown Valves for Sandy Service : Edition 4

$

208

BUY NOW

Placeholder headline

This is just a placeholder headline

API 510: Errata 2

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 16B Coiled Tubing, Snubbing and Wireline Well Intervention Equipment

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 5CT: Casing and Tubing w/ Addendum 1

$

518

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 5CT: Casing and Tubing Addendum 1

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 1161: Hazardous Liquid Pipeline Operator Qualification (OQ) : Edition 6

$

301

BUY NOW

ISO 4549:2023

ISO 4549:2023 Orthotics – Method for testing the reliability of microprocessor-controlled ankle moment units of ankle-foot orthoses

CDN $173.00

SKU: 73b353d1ded2 Categories: ,

Description

This document specifies a method for testing the reliability of microprocessor-controlled ankle moment units of ankle-foot orthosis, moving in plantar- and dorsiflexion direction.

This document specifies categories of locomotion profiles to be applied together with appropriate loading profiles, to generate plantar- and dorsiflexion ankle moment loads for the microprocessor-controlled ankle moment units. It also defines which measured outcome of the test allows to claim compliance to this document, and how the compliance is documented in the IFU.

This document solely addresses the resistance of microprocessor-controlled ankle moment units in motion. Geometrical constrains like end stops, where motion is stopped instead of sustaining it, can be tested in repetitive quasi static tests instead.

A method to derive test parameters for the reliability test of microprocessor-controlled ankle moment units is described.

This document is applicable to unilateral ankle-foot orthoses and to bilateral jointed orthoses where either both joints are controlled or where one joint is controlled and the other is not controlled.

Edition

1

Published Date

2023-07-24

Status

PUBLISHED

Pages

15

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies a method for testing the reliability of microprocessor-controlled ankle moment units of ankle-foot orthosis, moving in plantar- and dorsiflexion direction.

This document specifies categories of locomotion profiles to be applied together with appropriate loading profiles, to generate plantar- and dorsiflexion ankle moment loads for the microprocessor-controlled ankle moment units. It also defines which measured outcome of the test allows to claim compliance to this document, and how the compliance is documented in the IFU.

This document solely addresses the resistance of microprocessor-controlled ankle moment units in motion. Geometrical constrains like end stops, where motion is stopped instead of sustaining it, can be tested in repetitive quasi static tests instead.

A method to derive test parameters for the reliability test of microprocessor-controlled ankle moment units is described.

This document is applicable to unilateral ankle-foot orthoses and to bilateral jointed orthoses where either both joints are controlled or where one joint is controlled and the other is not controlled.