Your cart is currently empty!

ISO 4808:2021
ISO 4808:2021 Hydraulic fluid power – Interpolation method for particle count and filter test data
CDN $115.00
Description
This document describes a recommended method for the interpolation of particle concentration and filter Beta Ratio data when results are not otherwise available at the desired particle sizes. It is applicable for assessing conformance with existing fluid cleanliness and filter Beta Ratio specifications whereby the specification and actual test results are provided in different units of particle size, for example, the specification is in µm(c), but the particle counts or Beta Ratio data are in units of µm(b).
This document is also applicable when particle sizes in specifications and available data use the same units of particle size, but do not correspond to exactly the same sizes, for example, when particle counts at 20 µm(c) are specified, but data was collected at 21 µm(c). This method allows interpolation to intermediate particle sizes within the range of existing data and does not permit extrapolation to particle sizes outside the range of available data.
Edition
1
Published Date
2021-02-16
Status
PUBLISHED
Pages
12
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
This document describes a recommended method for the interpolation of particle concentration and filter Beta Ratio data when results are not otherwise available at the desired particle sizes. It is applicable for assessing conformance with existing fluid cleanliness and filter Beta Ratio specifications whereby the specification and actual test results are provided in different units of particle size, for example, the specification is in µm(c), but the particle counts or Beta Ratio data are in units of µm(b).
This document is also applicable when particle sizes in specifications and available data use the same units of particle size, but do not correspond to exactly the same sizes, for example, when particle counts at 20 µm(c) are specified, but data was collected at 21 µm(c). This method allows interpolation to intermediate particle sizes within the range of existing data and does not permit extrapolation to particle sizes outside the range of available data.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 16589:2011 Rotary shaft lip-type seals incorporating thermoplastic sealing elements – Part 2: Vocabulary
0 out of 5CDN $273.00 Add to cart -
ISO 4405:2022 Hydraulic fluid power – Fluid contamination – Determination of particulate contamination by the gravimetric method
0 out of 5CDN $173.00 Add to cart -
ISO 16908:2014 Hydraulic filter element test methods – Thermal conditioning and cold start-up simulation
0 out of 5CDN $173.00 Add to cart -
ISO 6194:2009 Rotary shaft lip-type seals incorporating elastomeric sealing elements – Part 2: Vocabulary
0 out of 5CDN $312.00 Add to cart