Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 4965:2012

ISO 4965:2012 Metallic materials – Dynamic force calibration for uniaxial fatigue testing – Part 2: Dynamic calibration device (DCD) instrumentation

CDN $115.00

SKU: ab595e2102f6 Category:

Description

In order to perform a dynamic calibration of a uniaxial testing system, it is necessary to measure the forces experienced by the test-piece to known levels of accuracy; this measurement is made by a dynamic calibration device (DCD) in place of the test-piece and the calibration method is described in ISO 4965-1. ISO 4965-2:2012 defines the calibration procedure for the DCD’s instrumentation. The method for the analysis of the results is also described, leading to a range of testing frequencies over which the instrumentation is valid for use with DCDs in accordance with ISO 4965-1.

Edition

1

Published Date

2012-07-06

Status

PUBLISHED

Pages

9

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

In order to perform a dynamic calibration of a uniaxial testing system, it is necessary to measure the forces experienced by the test-piece to known levels of accuracy; this measurement is made by a dynamic calibration device (DCD) in place of the test-piece and the calibration method is described in ISO 4965-1. ISO 4965-2:2012 defines the calibration procedure for the DCD's instrumentation. The method for the analysis of the results is also described, leading to a range of testing frequencies over which the instrumentation is valid for use with DCDs in accordance with ISO 4965-1.

Previous Editions

Can’t find what you are looking for?

Please contact us at: