ISO 51276:2019
ISO 51276:2019 Practice for use of a polymethylmethacrylate dosimetry system
CDN $76.00
Description
1.1 This is a practice for using polymethylmethacrylate (PMMA) dosimetry systems to measure absorbed dose in materials irradiated by photons or electrons in terms of absorbed dose to water. The PMMA dosimetry system is generally used as a routine dosimetry system.
1.2 The PMMA dosimeter is classified as a Type II dosim-eter on the basis of the complex effect of influence quantities (see ISO/ASTM Practice 52628).
1.3 This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ISO/ASTM 52628 “Prac-tice for Dosimetry in Radiation Processing” for a PMMA dosimetry system. It is intended to be read in conjunction with ISO/ASTM Practice 52628.
1.4 This practice covers the use of PMMA dosimetry systems under the following conditions:
1.4.1 the absorbed dose range is 0.1 kGy to 150 kGy.
1.4.2 the absorbed dose rate is1×10−2 to1×107 Gy·s−1.
1.4.3 the photon energy range is 0.1 to 25 MeV.
1.4.4 the electron energy range is 3 to 25 MeV.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for the Development of International Standards, Guides and Recom-mendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Edition
4
Published Date
2019-08-14
Status
PUBLISHED
Pages
6
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
1.1 This is a practice for using polymethylmethacrylate (PMMA) dosimetry systems to measure absorbed dose in materials irradiated by photons or electrons in terms of absorbed dose to water. The PMMA dosimetry system is generally used as a routine dosimetry system.
1.2 The PMMA dosimeter is classified as a Type II dosim-eter on the basis of the complex effect of influence quantities (see ISO/ASTM Practice 52628).
1.3 This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ISO/ASTM 52628 "Prac-tice for Dosimetry in Radiation Processing" for a PMMA dosimetry system. It is intended to be read in conjunction with ISO/ASTM Practice 52628.
1.4 This practice covers the use of PMMA dosimetry systems under the following conditions:
1.4.1 the absorbed dose range is 0.1 kGy to 150 kGy.
1.4.2 the absorbed dose rate is1×10−2 to1×107 Gy·s−1.
1.4.3 the photon energy range is 0.1 to 25 MeV.
1.4.4 the electron energy range is 3 to 25 MeV.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for the Development of International Standards, Guides and Recom-mendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 51818:2020 Practice for dosimetry in an electron beam facility for radiation processing at energies between 80 and 300 keV
0 out of 5CDN $173.00 Add to cart -
ISO 52949:2025 Additive manufacturing of metals – Qualification principles – Installation, operation and performance (IQ/OQ/PQ) of PBF-EB equipment
0 out of 5CDN $76.00 Add to cart -
ISO 51649:2015 Practice for dosimetry in an electron beam facility for radiation processing at energies between 300 keV and 25 MeV
0 out of 5CDN $273.00 Add to cart -
ISO 52303:2015 Guide for absorbed-dose mapping in radiation processing facilities
0 out of 5CDN $115.00 Add to cart