REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API SPEC 14L: Lock Mandrels and Landing Nipples : Reaffirmed

$

273

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 20F: Corrosion Resistant Bolting for Use in the Petroleum and Natural Gas Industries : Reaffirmed

$

169

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 5NCL Nickel Content Limits for API 5CT Sour Service Products

$

149

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 19ICD: Inflow Control Devices : Reaffirmed

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 23.2: Reconciliation of Liquid Tank Car(s) Quantities : Reaffirmed

$

218

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 16A: Specification for Drill-through Equipment

$

322

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-2: Field Testing Oil-based Drilling Fluids wA1

$

388

BUY NOW

ISO 51276:2019

ISO 51276:2019 Practice for use of a polymethylmethacrylate dosimetry system

CDN $76.00

SKU: bcfdaf0e28a0 Categories: ,

Description

1.1 This is a practice for using polymethylmethacrylate (PMMA) dosimetry systems to measure absorbed dose in materials irradiated by photons or electrons in terms of absorbed dose to water. The PMMA dosimetry system is generally used as a routine dosimetry system.

1.2 The PMMA dosimeter is classified as a Type II dosim-eter on the basis of the complex effect of influence quantities (see ISO/ASTM Practice 52628).

1.3 This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ISO/ASTM 52628 “Prac-tice for Dosimetry in Radiation Processing” for a PMMA dosimetry system. It is intended to be read in conjunction with ISO/ASTM Practice 52628.

1.4 This practice covers the use of PMMA dosimetry systems under the following conditions:

1.4.1 the absorbed dose range is 0.1 kGy to 150 kGy.

1.4.2 the absorbed dose rate is1×10−2 to1×107 Gy·s−1.

1.4.3 the photon energy range is 0.1 to 25 MeV.

1.4.4 the electron energy range is 3 to 25 MeV.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.

1.6 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for the Development of International Standards, Guides and Recom-mendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Edition

4

Published Date

2019-08-14

Status

PUBLISHED

Pages

6

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

1.1 This is a practice for using polymethylmethacrylate (PMMA) dosimetry systems to measure absorbed dose in materials irradiated by photons or electrons in terms of absorbed dose to water. The PMMA dosimetry system is generally used as a routine dosimetry system.

1.2 The PMMA dosimeter is classified as a Type II dosim-eter on the basis of the complex effect of influence quantities (see ISO/ASTM Practice 52628).

1.3 This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ISO/ASTM 52628 "Prac-tice for Dosimetry in Radiation Processing" for a PMMA dosimetry system. It is intended to be read in conjunction with ISO/ASTM Practice 52628.

1.4 This practice covers the use of PMMA dosimetry systems under the following conditions:

1.4.1 the absorbed dose range is 0.1 kGy to 150 kGy.

1.4.2 the absorbed dose rate is1×10−2 to1×107 Gy·s−1.

1.4.3 the photon energy range is 0.1 to 25 MeV.

1.4.4 the electron energy range is 3 to 25 MeV.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.

1.6 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for the Development of International Standards, Guides and Recom-mendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Previous Editions

Can’t find what you are looking for?

Please contact us at: