ISO 51310:2022
ISO 51310:2022 Practice for use of a radiochromic optical waveguide dosimetry system
CDN $82.00
Description
1.1 This is a practice for using a radiochromic optical waveguide dosimetry system to measure absorbed dose in materials irradiated by photons and high energy electrons in terms of absorbed dose to water. The radiochromic optical waveguide dosimetry system is generally used as a routine dosimetry system.
1.2 The optical waveguide dosimeter is classified as a Type II dosimeter on the basis of the complex effect of influence  quantities (see ISO/ASTM Practice 52628).
1.3 This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ISO/ASTM 52628 for an optical waveguide dosimetry system. It is intended to be read in conjunction with ISO/ASTM Practice 52628.
1.4 This practice applies to radiochromic optical waveguide dosimeters that can be used within part or all of the specified ranges as follows:
1.4.1 The absorbed dose range is from 1 Gy to 20 000 Gy.
1.4.2 The absorbed dose rate is from 0.001 Gy/s to 1000 Gy/s.
1.4.3 The radiation photon energy range is from 1 MeV to 10 MeV.
1.4.4 The radiation electron energy range is from 3 MeV to 25 MeV.
1.4.5 The irradiation temperature range is from –78 °C to +60 °C.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Edition
3
Published Date
2022-04-26
Status
PUBLISHED
Pages
6
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
1.1 This is a practice for using a radiochromic optical waveguide dosimetry system to measure absorbed dose in materials irradiated by photons and high energy electrons in terms of absorbed dose to water. The radiochromic optical waveguide dosimetry system is generally used as a routine dosimetry system.
1.2 The optical waveguide dosimeter is classified as a Type II dosimeter on the basis of the complex effect of influence  quantities (see ISO/ASTM Practice 52628).
1.3 This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ISO/ASTM 52628 for an optical waveguide dosimetry system. It is intended to be read in conjunction with ISO/ASTM Practice 52628.
1.4 This practice applies to radiochromic optical waveguide dosimeters that can be used within part or all of the specified ranges as follows:
1.4.1 The absorbed dose range is from 1 Gy to 20 000 Gy.
1.4.2 The absorbed dose rate is from 0.001 Gy/s to 1000 Gy/s.
1.4.3 The radiation photon energy range is from 1 MeV to 10 MeV.
1.4.4 The radiation electron energy range is from 3 MeV to 25 MeV.
1.4.5 The irradiation temperature range is from –78 °C to +60 °C.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 51538:2017 Practice for use of the ethanol-chlorobenzene dosimetry system
CDN $124.00 Add to cart -

ISO 51940:2022 Guidance for dosimetry for sterile insects release programs
CDN $124.00 Add to cart -

ISO 52926:2023 Additive manufacturing of metals – Qualification principles – Part 1: General qualification of operators
CDN $124.00 Add to cart -

ISO 51205:2017 Practice for use of a ceric-cerous sulfate dosimetry system
CDN $124.00 Add to cart