REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 670: Machinery Protection Systems

$

423

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.5: Guidelines for Cargo Analysis and Reconciliation

$

252

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 603: Corrosion-Resistant, Bolted Bonnet Gate Valves–Flanged and Butt-Welding Ends

$

205

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction

$

460

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 12R1: Installation, Operation, Maintenance, Inspection, and Repair of Tanks in Production Service

$

285

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction: Addendum 4

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 9A: Specification for Wire Rope

$

248

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 575: Inspection Practices for Atmospheric and Low-Pressure Storage Tanks

$

416

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 9A: Addenda 2

$

0

BUY NOW

ISO 5725:2020

ISO 5725:2020 Accuracy (trueness and precision) of measurement methods and results – Part 4: Basic methods for the determination of the trueness of a standard measurement method

CDN $233.00

SKU: c43e6b509474 Categories: ,

Description

1.1 This document

– specifies basic methods for estimating the bias of a measurement method and the laboratory bias when a measurement method is applied;

– provides a practical approach of a basic method for routine use in estimating the bias of measurement methods and laboratory bias;

– provides a brief guidance to all personnel concerned with designing, performing or analysing the results of the measurements for estimating bias.

1.2 It is concerned exclusively with measurement methods which yield measurements on a continuous scale and give a single value as the measurement result, although the single value can be the outcome of a calculation from a set of observations.

1.3 This document applies when the measurement method has been standardized and all measurements are carried out according to that measurement method.

NOTE In ISO/IEC Guide 99:2007(VIM), “measurement procedure” (2.6) is an analogous term related to the term “measurement method” used in this document.

1.4 This document applies only if an accepted reference value can be established to substitute the true value by using the value, for example:

– of a suitable reference material;

– of a suitable measurement standard;

– referring to a suitable measurement method;

– of a suitable prepared known sample.

1.5 This document applies only to the cases where it is sufficient to estimate bias on one property at a time. It is not applicable if the bias in the measurement of one property is affected by the level of any other property (i.e. it does not consider interferences by any influencing quantity). Comparison of the trueness of two-measurement methods is considered in ISO 5725-6.

Edition

2

Published Date

2020-03-26

Status

PUBLISHED

Pages

26

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

1.1 This document

- specifies basic methods for estimating the bias of a measurement method and the laboratory bias when a measurement method is applied;

- provides a practical approach of a basic method for routine use in estimating the bias of measurement methods and laboratory bias;

- provides a brief guidance to all personnel concerned with designing, performing or analysing the results of the measurements for estimating bias.

1.2 It is concerned exclusively with measurement methods which yield measurements on a continuous scale and give a single value as the measurement result, although the single value can be the outcome of a calculation from a set of observations.

1.3 This document applies when the measurement method has been standardized and all measurements are carried out according to that measurement method.

NOTE In ISO/IEC Guide 99:2007(VIM), "measurement procedure" (2.6) is an analogous term related to the term "measurement method" used in this document.

1.4 This document applies only if an accepted reference value can be established to substitute the true value by using the value, for example:

- of a suitable reference material;

- of a suitable measurement standard;

- referring to a suitable measurement method;

- of a suitable prepared known sample.

1.5 This document applies only to the cases where it is sufficient to estimate bias on one property at a time. It is not applicable if the bias in the measurement of one property is affected by the level of any other property (i.e. it does not consider interferences by any influencing quantity). Comparison of the trueness of two-measurement methods is considered in ISO 5725-6.