ISO 7027:2016
ISO 7027:2016 Water quality – Determination of turbidity – Part 1: Quantitative methods
CDN $130.00
Description
ISO 7027-1:2016 specifies two quantitative methods using optical turbidimeters or nephelometers for the determination of turbidity of water:
a) nephelometry, procedure for measurement of diffuse radiation, applicable to water of low turbidity (for example drinking water);
b) turbidimetry, procedure for measurement of the attenuation of a radiant flux, more applicable to highly turbid waters (for example waste waters or other cloudy waters).
Turbidities measured according to the first method are presented as nephelometric turbidity units (NTU). The results typically range between <0,05 NTU and 400 NTU. Depending on the instrument design, it can also be applicable to waters of higher turbidity. There is numerical equivalence of the units NTU and formazin nephelometric unit (FNU).
Turbidity measured by the second method is expressed in formazin attenuation units (FAU), results typically range between 40 FAU and 4 000 FAU.
Edition
1
Published Date
2016-06-09
Status
PUBLISHED
Pages
9
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 7027-1:2016 specifies two quantitative methods using optical turbidimeters or nephelometers for the determination of turbidity of water:
a) nephelometry, procedure for measurement of diffuse radiation, applicable to water of low turbidity (for example drinking water);
b) turbidimetry, procedure for measurement of the attenuation of a radiant flux, more applicable to highly turbid waters (for example waste waters or other cloudy waters).
Turbidities measured according to the first method are presented as nephelometric turbidity units (NTU). The results typically range between <0,05 NTU and 400 NTU. Depending on the instrument design, it can also be applicable to waters of higher turbidity. There is numerical equivalence of the units NTU and formazin nephelometric unit (FNU).
Turbidity measured by the second method is expressed in formazin attenuation units (FAU), results typically range between 40 FAU and 4 000 FAU.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 10704:2019 Water quality – Gross alpha and gross beta activity – Test method using thin source deposit
CDN $261.00 Add to cart -

ISO 13161:2020 Water quality – Polonium 210 – Test method using alpha spectrometry
CDN $261.00 Add to cart -

ISO 4722:2023 Water quality – Thorium 232 – Part 1: Test method using alpha spectrometry
CDN $193.00 Add to cart -

ISO 22017:2020 Water quality – Guidance for rapid radioactivity measurements in nuclear or radiological emergency situation
CDN $261.00 Add to cart