REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API TR 2583 : Measurement of Produced Water for Custody Transfer

$

174

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 2581: Wet Gas Sampling

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 2581 Wet Gas Sampling : Errata 1

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API 510: Pressure Vessel Inspection Code: In-service Inspection, Rating, Repair, and Alteration

$

481

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 6AV1: Validation of Safety and Shutdown Valves for Sandy Service : Edition 4

$

208

BUY NOW

Placeholder headline

This is just a placeholder headline

API 510: Errata 2

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 16B Coiled Tubing, Snubbing and Wireline Well Intervention Equipment

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 5CT: Casing and Tubing w/ Addendum 1

$

518

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 5CT: Casing and Tubing Addendum 1

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 1161: Hazardous Liquid Pipeline Operator Qualification (OQ) : Edition 6

$

301

BUY NOW

ISO 7637:2016

ISO 7637:2016 Road vehicles – Electrical disturbances from conduction and coupling – Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines

CDN $233.00

SKU: 84a6374f6626 Categories: ,

Description

ISO 7637-3:2016 defines bench test methods to evaluate the immunity of devices under test (DUTs) to transient pulses coupled to lines other than supply lines. The test pulses simulate both fast and slow transient disturbances caused by the switching of inductive loads and relay contact bounce.

The following three test methods are described in ISO 7637-3:2016:

– capacitive coupling clamp (CCC) method;

– direct capacitive coupling (DCC) method;

– inductive coupling clamp (ICC) method.

ISO 7637-3:2016 applies to road vehicles fitted with nominal 12 V or 24 V electrical systems.

For transient pulses immunity, Annex B provides recommended test severity levels in line with the functional performance status classification (FPSC) principle described in ISO 7637‚Äë1.

Edition

3

Published Date

2016-07-01

Status

PUBLISHED

Pages

25

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 7637-3:2016 defines bench test methods to evaluate the immunity of devices under test (DUTs) to transient pulses coupled to lines other than supply lines. The test pulses simulate both fast and slow transient disturbances caused by the switching of inductive loads and relay contact bounce.

The following three test methods are described in ISO 7637-3:2016:

- capacitive coupling clamp (CCC) method;

- direct capacitive coupling (DCC) method;

- inductive coupling clamp (ICC) method.

ISO 7637-3:2016 applies to road vehicles fitted with nominal 12 V or 24 V electrical systems.

For transient pulses immunity, Annex B provides recommended test severity levels in line with the functional performance status classification (FPSC) principle described in ISO 7637‚Äë1.