ISO 80005:2019
ISO 80005:2019 Utility connections in port – Part 1: High voltage shore connection (HVSC) systems – General requirements
CDN $644.00
Description
IEC/IEEE 80005-1:2019 describes high-voltage shore connection (HVSC) systems, onboard the ship and on shore, to supply the ship with electrical power from shore. This document is applicable to the design, installation and testing of HVSC systems and addresses:
– HV shore distribution systems,
– shore-to-ship connection and interface equipment,
– transformers/reactors,
– semiconductor/rotating frequency convertors,
– ship distribution systems, and
– control, monitoring, interlocking and power management systems.
It does not apply to the electrical power supply during docking periods, for example dry docking and other out of service maintenance and repair. Additional and/or alternative requirements can be imposed by national administrations or the authorities within whose jurisdiction the ship is intended to operate and/or by the owners or authorities responsible for a shore supply or distribution system. It is expected that HVSC systems will have practicable applications for ships requiring 1 MVA or more or ships with HV main supply. Low-voltage shore connection systems are not covered by this document. This second edition cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) modification of 4.1, Figure 1: transformer on ship is optional, earthing switches on ship removed;
b) 4.2.2 and new item 11.3: alternative procedure of periodic testing added;
c) modification of 4.9:
– minimum current value in the safety circuits shall be 50 mA;
– opening of safety loop shall cause the automatic opening of ship and shore HVSC circuit breakers in a maximum time of 200 ms;
d) modification of 5.2: added Figure on harmonic contents;
e) modification of 6.2.3:
earthing transformer with resistor can be used also on the secondary side;
neutral earthing resistor rating in amperes shall be minimum 25 A, 5 s;
f) modification of all annexes: the safety circuits shall be mandatory;
g) modification of A.2.1: a metallic shield shall be installed at least on the power cores or common on pilot wires;
h) modification of B.7.2.1: new safety circuit introduced: single line diagram and description;
i) modification of C.4.1: SLD for cruise ships was updated, also the safety circuits to be coherent with main body, IEC symbols and introduced more details about the control socket-outlets and plugs manufacturer type;
j) modification of C.7.3.1:
– shore power connector pin assignment is updated;
– all cruise ships shall use 4 cables in all cases;
k) added D.6.1: the supply point on shore can be fixed or movable;
l) modification of D.7.3.2: the voltage used in the pilot circuit for container ships shall be less than 60 V DC or 25 V AC.
m) added D.8.6 and D.9.3.1: automatic restart and synchronization alternatives;
n) Annex E set to informative;
o) Annex F set to informative.
Edition
2
Published Date
2019-03-22
Status
PUBLISHED
Pages
145
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
IEC/IEEE 80005-1:2019 describes high-voltage shore connection (HVSC) systems, onboard the ship and on shore, to supply the ship with electrical power from shore. This document is applicable to the design, installation and testing of HVSC systems and addresses: - HV shore distribution systems, - shore-to-ship connection and interface equipment, - transformers/reactors, - semiconductor/rotating frequency convertors, - ship distribution systems, and - control, monitoring, interlocking and power management systems. It does not apply to the electrical power supply during docking periods, for example dry docking and other out of service maintenance and repair. Additional and/or alternative requirements can be imposed by national administrations or the authorities within whose jurisdiction the ship is intended to operate and/or by the owners or authorities responsible for a shore supply or distribution system. It is expected that HVSC systems will have practicable applications for ships requiring 1 MVA or more or ships with HV main supply. Low-voltage shore connection systems are not covered by this document. This second edition cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) modification of 4.1, Figure 1: transformer on ship is optional, earthing switches on ship removed; b) 4.2.2 and new item 11.3: alternative procedure of periodic testing added; c) modification of 4.9: - minimum current value in the safety circuits shall be 50 mA; - opening of safety loop shall cause the automatic opening of ship and shore HVSC circuit breakers in a maximum time of 200 ms; d) modification of 5.2: added Figure on harmonic contents; e) modification of 6.2.3: earthing transformer with resistor can be used also on the secondary side; neutral earthing resistor rating in amperes shall be minimum 25 A, 5 s; f) modification of all annexes: the safety circuits shall be mandatory; g) modification of A.2.1: a metallic shield shall be installed at least on the power cores or common on pilot wires; h) modification of B.7.2.1: new safety circuit introduced: single line diagram and description; i) modification of C.4.1: SLD for cruise ships was updated, also the safety circuits to be coherent with main body, IEC symbols and introduced more details about the control socket-outlets and plugs manufacturer type; j) modification of C.7.3.1: - shore power connector pin assignment is updated; - all cruise ships shall use 4 cables in all cases; k) added D.6.1: the supply point on shore can be fixed or movable; l) modification of D.7.3.2: the voltage used in the pilot circuit for container ships shall be less than 60 V DC or 25 V AC. m) added D.8.6 and D.9.3.1: automatic restart and synchronization alternatives; n) Annex E set to informative; o) Annex F set to informative.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 15424:2025 Information technology – Automatic identification and data capture techniques – Data carrier identifiers (including symbology identifiers)
CDN $233.00 Add to cart -

ISO 8927:1991 Earth-moving machinery – Machine availability – Vocabulary
CDN $233.00 Add to cart -

ISO 8384:2019 Ships and marine technology – Dredgers – Vocabulary
CDN $76.00 Add to cart -

ISO 80004:2020 Nanotechnologies – Vocabulary – Part 3: Carbon nano-objects
CDN $76.00 Add to cart