REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API TR 2583 : Measurement of Produced Water for Custody Transfer

$

174

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 2581: Wet Gas Sampling

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 2581 Wet Gas Sampling : Errata 1

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API 510: Pressure Vessel Inspection Code: In-service Inspection, Rating, Repair, and Alteration

$

481

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 6AV1: Validation of Safety and Shutdown Valves for Sandy Service : Edition 4

$

208

BUY NOW

Placeholder headline

This is just a placeholder headline

API 510: Errata 2

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 16B Coiled Tubing, Snubbing and Wireline Well Intervention Equipment

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 5CT: Casing and Tubing w/ Addendum 1

$

518

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 5CT: Casing and Tubing Addendum 1

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 1161: Hazardous Liquid Pipeline Operator Qualification (OQ) : Edition 6

$

301

BUY NOW

ISO 80369:2021

ISO 80369:2021 Small-bore connectors for liquids and gases in healthcare applications – Part 7: Connectors for intravascular or hypodermic applications

CDN $312.00

SKU: cf03ec65757c Category:

Description

This document specifies dimensions and requirements for the design and functional performance of small-bore connectors intended to be used for connections in intravascular applications or hypodermic connections in hypodermic applications of medical devices and accessories.

EXAMPLES Hypodermic syringes and needles or intravascular (IV) cannulae with male and female Luer slip connectors and Luer lock connectors.

NOTE 1 See Annex A.

NOTE 2 The Luer connector was originally designed for use at pressures up to 300 kPa.

This document does not specify requirements for themedical devices or accessories that use these connectors. Such requirements are given in particular documents for specific medical devices or accessories.

This document does not specify requirements for the following small-bore connectors, which are specified in other documents:

– haemodialyser, haemodiafilter and haemofilter blood compartment ports (ISO 8637 [5] and applicable portion of ISO 8638 [ 6] referencing blood compartment ports);

– haemodialysis, haemodiafiltration and haemofiltration equipment connectors (ISO 8637 [5]);

– infusion system closure piercing connectors (ISO 8536-4 [4]).

NOTE 3 Manufacturers are encouraged to incorporate thesmall-bore connectors specified in this document into medical devices or accessories, even if currently not required by the relevant particular medical device documents. It is expected that when the relevant particular medical device documents are revised, requirements for small-bore connectors, as specified in ISO 80369, will be included.

NOTE 4 ISO 80369-1:2018, Clause 7, specifies alternative methods of conformance with ISO 80369-1:2018, for small-bore connectors intended for use with intravascular applications or hypodermic application medical devices or accessories, which do not conform with this document.

Edition

2

Published Date

2021-05-04

Status

PUBLISHED

Pages

47

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies dimensions and requirements for the design and functional performance of small-bore connectors intended to be used for connections in intravascular applications or hypodermic connections in hypodermic applications of medical devices and accessories.

EXAMPLES Hypodermic syringes and needles or intravascular (IV) cannulae with male and female Luer slip connectors and Luer lock connectors.

NOTE 1 See Annex A.

NOTE 2 The Luer connector was originally designed for use at pressures up to 300 kPa.

This document does not specify requirements for themedical devices or accessories that use these connectors. Such requirements are given in particular documents for specific medical devices or accessories.

This document does not specify requirements for the following small-bore connectors, which are specified in other documents:

- haemodialyser, haemodiafilter and haemofilter blood compartment ports (ISO 8637 [5] and applicable portion of ISO 8638 [ 6] referencing blood compartment ports);

- haemodialysis, haemodiafiltration and haemofiltration equipment connectors (ISO 8637 [5]);

- infusion system closure piercing connectors (ISO 8536-4 [4]).

NOTE 3 Manufacturers are encouraged to incorporate thesmall-bore connectors specified in this document into medical devices or accessories, even if currently not required by the relevant particular medical device documents. It is expected that when the relevant particular medical device documents are revised, requirements for small-bore connectors, as specified in ISO 80369, will be included.

NOTE 4 ISO 80369-1:2018, Clause 7, specifies alternative methods of conformance with ISO 80369-1:2018, for small-bore connectors intended for use with intravascular applications or hypodermic application medical devices or accessories, which do not conform with this document.

Previous Editions

Can’t find what you are looking for?