ISO 8249:2018
ISO 8249:2018 Welding – Determination of Ferrite Number (FN) in austenitic and duplex ferritic-austenitic Cr-Ni stainless steel weld metals
CDN $273.00
Description
This document specifies the method and apparatus for:
– the measurement of the delta ferrite content, expressed as Ferrite Number (FN), in largely austenitic and duplex ferritic-austenitic stainless steel[1] weld metal through the attractive force between a weld metal sample and a standard permanent magnet;
– the preparation and measurement of standard pads for manual metal arc covered electrodes. The general method is also recommended for the ferrite measurement of production welds and for weld metal from other processes, such as gas tungsten arc welding, gas shielded metal arc welding and submerged arc welding (in these cases, the way of producing the pad should be defined);
– the calibration of other instruments to measure FN.
The method laid down in this document is intended for use on weld metals in the as-welded state and on weld metals after thermal treatments causing complete or partial transformation of ferrite to any non-magnetic phase. Austenitizing thermal treatments which alter the size and shape of the ferrite change the magnetic response of the ferrite.
The method is not intended for measurement of the ferrite content of cast, forged or wrought austenitic or duplex ferritic-austenitic steel samples.
[1] The term “austenitic-ferritic (duplex) stainless steel” is sometimes applied in place of “duplex ferritic-austenitic stainless steel”.
Edition
3
Published Date
2018-08-10
Status
PUBLISHED
Pages
27
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document specifies the method and apparatus for:
- the measurement of the delta ferrite content, expressed as Ferrite Number (FN), in largely austenitic and duplex ferritic-austenitic stainless steel[1] weld metal through the attractive force between a weld metal sample and a standard permanent magnet;
- the preparation and measurement of standard pads for manual metal arc covered electrodes. The general method is also recommended for the ferrite measurement of production welds and for weld metal from other processes, such as gas tungsten arc welding, gas shielded metal arc welding and submerged arc welding (in these cases, the way of producing the pad should be defined);
- the calibration of other instruments to measure FN.
The method laid down in this document is intended for use on weld metals in the as-welded state and on weld metals after thermal treatments causing complete or partial transformation of ferrite to any non-magnetic phase. Austenitizing thermal treatments which alter the size and shape of the ferrite change the magnetic response of the ferrite.
The method is not intended for measurement of the ferrite content of cast, forged or wrought austenitic or duplex ferritic-austenitic steel samples.
[1] The term "austenitic-ferritic (duplex) stainless steel" is sometimes applied in place of "duplex ferritic-austenitic stainless steel".
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 17636:2022 Non-destructive testing of welds – Radiographic testing – Part 2: X- and gamma-ray techniques with digital detectors
CDN $351.00 Add to cart -

ISO 10675:2021 Non-destructive testing of welds – Acceptance levels for radiographic testing – Part 1: Steel, nickel, titanium and their alloys
CDN $173.00 Add to cart -

ISO 13919:2019 Electron and laser-beam welded joints – Requirements and recommendations on quality levels for imperfections – Part 1: Steel, nickel, titanium and their alloys
CDN $173.00 Add to cart -

ISO 18785:2018 Friction stir spot welding – Aluminium – Part 1: Vocabulary
CDN $76.00 Add to cart