ISO 834:2000

ISO 834:2000 Fire-resistance tests – Elements of building construction – Part 6: Specific requirements for beams

CDN $131.00

SKU: 73d584a8bdb4 Categories: ,

Description

This part of ISO 834 specifies the procedures to be followed for determining the fire resistance of beams, when

tested on their own.

Beams are normally tested with their underside and two vertical sides fully exposed to heating. However, when the

exposure is from four sides or less than three sides, appropriate exposure conditions are necessary. Beams which

are part of a floor construction are tested with the floor construction as described in ISO 834-5 and are subject to

evaluation of integrity and insulation.

The application of this test to other untested forms of construction is acceptable when the construction complies

with the direct field of application as given in this part of ISO 834 or when subjected to an extended application

analysis in accordance with ISO/TR 12470. Since ISO/TR 12470 gives only general guidelines, specific extended

application analyses are to be performed only by persons expert in fire-resistant constructions.

General guidance on this test method is given in annex A.

Edition

1

Published Date

2000-08-17

Status

PUBLISHED

Pages

12

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This part of ISO 834 specifies the procedures to be followed for determining the fire resistance of beams, when

tested on their own.

Beams are normally tested with their underside and two vertical sides fully exposed to heating. However, when the

exposure is from four sides or less than three sides, appropriate exposure conditions are necessary. Beams which

are part of a floor construction are tested with the floor construction as described in ISO 834-5 and are subject to

evaluation of integrity and insulation.

The application of this test to other untested forms of construction is acceptable when the construction complies

with the direct field of application as given in this part of ISO 834 or when subjected to an extended application

analysis in accordance with ISO/TR 12470. Since ISO/TR 12470 gives only general guidelines, specific extended

application analyses are to be performed only by persons expert in fire-resistant constructions.

General guidance on this test method is given in annex A.