REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 12R1: Installation, Operation, Maintenance, Inspection, and Repair of Tanks in Production Service

$

285

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report 2583 – Measurement of Produced Water for Custody Transfer

$

174

BUY NOW

Placeholder headline

This is just a placeholder headline

API Bulletin 592 – Elements of a Fixed Equipment Mechanical Integrity (FE MI) Program

$

142

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC Q1: Addenda 2

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 2583 : Measurement of Produced Water for Custody Transfer

$

174

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 2581: Wet Gas Sampling

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 2581 Wet Gas Sampling : Errata 1

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API 510: Pressure Vessel Inspection Code: In-service Inspection, Rating, Repair, and Alteration

$

481

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 6AV1: Validation of Safety and Shutdown Valves for Sandy Service : Edition 4

$

208

BUY NOW

ISO 8467:1993

ISO 8467:1993 Water quality – Determination of permanganate index

CDN $76.00

SKU: 05a0c4663a53 Category:

Description

The principle of the method specified is heating a sample in a boiling water-bath with a known amount of potassium permanganate und sulfuric acid for a fixed period time (10 min), reducing part of the permanganate by oxidizable material in the sample and determining the consumed permanganate by addition of an excess of oxalate solution, followed by titration with permanganate. Applies to waters having a cloride ion concentration of less than 300 mg/l. Samples having a permanganate index over 10 mg/l should be diluted before analysis. The lower limit of the optimum range of the test is 0,5 mg/l.

Edition

2

Published Date

1993-06-03

Status

PUBLISHED

Pages

4

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

The principle of the method specified is heating a sample in a boiling water-bath with a known amount of potassium permanganate und sulfuric acid for a fixed period time (10 min), reducing part of the permanganate by oxidizable material in the sample and determining the consumed permanganate by addition of an excess of oxalate solution, followed by titration with permanganate. Applies to waters having a cloride ion concentration of less than 300 mg/l. Samples having a permanganate index over 10 mg/l should be diluted before analysis. The lower limit of the optimum range of the test is 0,5 mg/l.