Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 9236:2004

ISO 9236:2004 Photography – Sensitometry of screen/film systems for medical radiography – Part 1: Determination of sensitometric curve shape, speed and average gradient

CDN $251.00

SKU: 290f08fc4486 Category:

Description

ISO 9236-1:2004 specifies methods for the determination of the sensitometric curve shape, average gradient and speed of a single sample of a screen/film/filmholder/processing system for medical radiography. It is not applicable to special radiographic applications such as mammography, dental radiography and direct-exposing medical radiographic systems (see for example ISO 5799).

The filmholder can be any means that ensures close screen/film contact and prevents the film from being exposed to ambient light. In particular, the filmholder can be a light-tight vacuum bag, as often used in the laboratory, or a radiographic cassette as used in medical radiography.

Edition

2

Published Date

2004-01-27

Status

PUBLISHED

Pages

20

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO 9236-1:2004 specifies methods for the determination of the sensitometric curve shape, average gradient and speed of a single sample of a screen/film/filmholder/processing system for medical radiography. It is not applicable to special radiographic applications such as mammography, dental radiography and direct-exposing medical radiographic systems (see for example ISO 5799).

The filmholder can be any means that ensures close screen/film contact and prevents the film from being exposed to ambient light. In particular, the filmholder can be a light-tight vacuum bag, as often used in the laboratory, or a radiographic cassette as used in medical radiography.

Previous Editions

Can’t find what you are looking for?

Please contact us at: