Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 9584:2023

ISO 9584:2023 Implants for surgery – Non-destructive testing – Radiographic examination of cast metallic surgical implants

CDN $115.00

SKU: b416e7573ecd Category:

Description

This document establishes a method for detecting and evaluating internal imperfections of cast metallic surgical implants and related weldments.

The procedures established in this document apply to film-based methods.

The recommendations on the acceptance limits for internal imperfections in cast metallic surgical implants are given in Annex A.

NOTE   In this document, when not otherwise specified, the term “manufacturer” refers to the “implant manufacturer”, and the term “product” refers to the “metallic cast implant for surgery” or to the “component of metallic cast implant for surgery”.

Edition

2

Published Date

2023-10-17

Status

PUBLISHED

Pages

7

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document establishes a method for detecting and evaluating internal imperfections of cast metallic surgical implants and related weldments.

The procedures established in this document apply to film-based methods.

The recommendations on the acceptance limits for internal imperfections in cast metallic surgical implants are given in Annex A.

NOTE   In this document, when not otherwise specified, the term “manufacturer” refers to the “implant manufacturer”, and the term “product” refers to the “metallic cast implant for surgery” or to the “component of metallic cast implant for surgery”.

Previous Editions

Can’t find what you are looking for?

Please contact us at: