Search
×
FR

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-6 Chapter 6 – Density

$

204

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 560: Fired Heaters for General Refinery Services

$

721

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 64: Diverter Equipment Systems

$

324

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 17.10.1: Refrigerated Light Hydrocarbon Fluids – Measurement of Cargoes on Board LNG Carries

$

417

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-1: Testing Water-based Drilling Fluids

$

418

BUY NOW

Placeholder headline

This is just a placeholder headline

API Technical Report TDB-12 Chapter 12 – Thermal Conductivity

$

214

BUY NOW

Placeholder headline

This is just a placeholder headline

API 16FI Frac Iron Guidelines and Requirements

$

129

BUY NOW

ISO 98:2012

ISO 98:2012 Uncertainty of measurement – Part 4: Role of measurement uncertainty in conformity assessment

CDN $312.00

SKU: 53d76da0dc95 Category:

Description

ISO/IEC Guide 98-4:2012 provides guidance and procedures for assessing the conformity of an item (entity, object or system) with specified requirements. The item might be, for example, a gauge block, a grocery scale or a blood sample. The procedures can be applied where the following conditions exist: the item is distinguished by a single scalar quantity (a measurable property) defined to a level of detail sufficient to be reasonably represented by an essentially unique true value; an interval of permissible values of the property is specified by one or two tolerance limits; the property can be measured and the measurement result expressed in a manner consistent with the principles of the GUM, so that knowledge of the value of the property can be reasonably described by (a) a probability density function, (b) a distribution function, (c) numerical approximations to such functions, or (d) a best estimate, together with a coverage interval and an associated coverage probability.

The procedures developed in this document can be used to realize an interval, called an acceptance interval, of permissible measured values of the property of interest. Acceptance limits can be chosen so as to balance the risks associated with accepting non-conforming items (consumer’s risk) or rejecting conforming items (producer’s risk).

Two types of conformity assessment problems are addressed. The first is the setting of acceptance limits that will assure that a desired conformance probability for a single measured item is achieved. The second is the setting of acceptance limits to assure an acceptable level of confidence on average as a number of (nominally identical) items are measured. Guidance is given for their solution.

This document contains examples to illustrate the guidance provided. The concepts presented can be extended to more general conformity assessment problems based on measurements of a set of scalar measurands. The audience of this document includes quality managers, members of standards development organizations, accreditation authorities and the staffs of testing and measuring laboratories, inspection bodies, certification bodies, regulatory agencies, academics and researchers.

Edition

1

Published Date

2012-11-19

Status

PUBLISHED

Pages

49

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

ISO/IEC Guide 98-4:2012 provides guidance and procedures for assessing the conformity of an item (entity, object or system) with specified requirements. The item might be, for example, a gauge block, a grocery scale or a blood sample. The procedures can be applied where the following conditions exist: the item is distinguished by a single scalar quantity (a measurable property) defined to a level of detail sufficient to be reasonably represented by an essentially unique true value; an interval of permissible values of the property is specified by one or two tolerance limits; the property can be measured and the measurement result expressed in a manner consistent with the principles of the GUM, so that knowledge of the value of the property can be reasonably described by (a) a probability density function, (b) a distribution function, (c) numerical approximations to such functions, or (d) a best estimate, together with a coverage interval and an associated coverage probability.

The procedures developed in this document can be used to realize an interval, called an acceptance interval, of permissible measured values of the property of interest. Acceptance limits can be chosen so as to balance the risks associated with accepting non-conforming items (consumer's risk) or rejecting conforming items (producer's risk).

Two types of conformity assessment problems are addressed. The first is the setting of acceptance limits that will assure that a desired conformance probability for a single measured item is achieved. The second is the setting of acceptance limits to assure an acceptable level of confidence on average as a number of (nominally identical) items are measured. Guidance is given for their solution.

This document contains examples to illustrate the guidance provided. The concepts presented can be extended to more general conformity assessment problems based on measurements of a set of scalar measurands. The audience of this document includes quality managers, members of standards development organizations, accreditation authorities and the staffs of testing and measuring laboratories, inspection bodies, certification bodies, regulatory agencies, academics and researchers.

Previous Editions

Can’t find what you are looking for?

Please contact us at: