Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

ISO 9978:2020

ISO 9978:2020 Radiation protection – Sealed sources – Leakage test methods

CDN $186.00

SKU: a6b2b219952f Category:

Description

This document specifies the different leakage test methods for sealed sources. It gives a comprehensive set of procedures using radioactive and non-radioactive means.

This document applies to the following situations:

– leakage testing of test sources following design classification testing in accordance with ISO 2919[1];

– production quality control testing of sealed sources;

– periodic inspections of the sealed sources performed at regular intervals, during the working life.

Annex A of this document gives guidance to the user in the choice of the most suitable method(s) according to situation and source type.

It is recognized that there can be circumstances where special tests, not described in this document, are required.

It is emphasized, however, that insofar as production, use, storage and transport of sealed radioactive sources are concerned, compliance with this document is no substitute for complying with the requirements of the relevant IAEA regulations[17] and other relevant national regulations. It is also recognized that countries can enact statutory regulations which specify exemptions for tests, according to sealed source type, design, working environment, and activity (e.g., for very low activity reference sources where the total activity is less than the leakage test limit).

Edition

2

Published Date

2020-07-03

Status

PUBLISHED

Pages

13

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies the different leakage test methods for sealed sources. It gives a comprehensive set of procedures using radioactive and non-radioactive means.

This document applies to the following situations:

- leakage testing of test sources following design classification testing in accordance with ISO 2919[1];

- production quality control testing of sealed sources;

- periodic inspections of the sealed sources performed at regular intervals, during the working life.

Annex A of this document gives guidance to the user in the choice of the most suitable method(s) according to situation and source type.

It is recognized that there can be circumstances where special tests, not described in this document, are required.

It is emphasized, however, that insofar as production, use, storage and transport of sealed radioactive sources are concerned, compliance with this document is no substitute for complying with the requirements of the relevant IAEA regulations[17] and other relevant national regulations. It is also recognized that countries can enact statutory regulations which specify exemptions for tests, according to sealed source type, design, working environment, and activity (e.g., for very low activity reference sources where the total activity is less than the leakage test limit).