Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

B51-14 (R2019) – Boiler, pressure vessel, and pressure piping code

$

362

BUY NOW

ANSI Z21.22-2015 (R2025)/CSA 4.4-2015 (R2025)

ANSI Z21.22-2015 (R2025)/CSA 4.4-2015 (R2025) – Relief valves for hot water supply systems

CDN $542.00

Relief valves for hot water supply systems

SKU: 2423731 Categories: ,

Description

Preface This is the second edition of ANSI Z21.22-2015 / CSA 4.4-2015, Relief valves for hot water supply systems. This Standard was prepared by the Z21/CSA Joint Technical Advisory Group on Standards for Gas-Fired Water Heaters under the jurisdiction of the Technical Committee on Gas Appliances and Related Accessories, the Z21/83 Technical Committee on Performance and Installation of Gas Burning Appliances and Related Accessories, and the Strategic Steering Committee on Standards for Fuel Burning Appliances, and had been formally approved by the Technical Committee(s), and American National Standards Institute. Scope 1.1 This Standard applies to the following types of relief valves constructed entirely of new, unused parts and materials:  a) combination temperature and pressure relief valves for use on storage tanks of hot water supply systems without heater input limitation, hereinafter called “T&P” valves;  b) valves having only pressure relief features for use on storage tanks of hot water supply systems without heater input limitation; and  c) vacuum relief valves.  1.2 A T&P valve operates when the temperature sensing element is at 210 °F (99 °C) or less. A device with a higher operating temperature is not acceptable under this Standard.  1.3 A vacuum relief valve is a single-purpose type.  1.4 All references to psi throughout this Standard are to be considered gage pressures unless otherwise specified.  1.5 Clause 9 contains provisions that are unique to Canada.  1.6 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user shall satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard.  Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.  Notes to tables and figures are considered part of the table or figure and may be written as requirements.  Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

44

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the second edition of ANSI Z21.22-2015 / CSA 4.4-2015, Relief valves for hot water supply systems. This Standard was prepared by the Z21/CSA Joint Technical Advisory Group on Standards for Gas-Fired Water Heaters under the jurisdiction of the Technical Committee on Gas Appliances and Related Accessories, the Z21/83 Technical Committee on Performance and Installation of Gas Burning Appliances and Related Accessories, and the Strategic Steering Committee on Standards for Fuel Burning Appliances, and had been formally approved by the Technical Committee(s), and American National Standards Institute. Scope 1.1 This Standard applies to the following types of relief valves constructed entirely of new, unused parts and materials:  a) combination temperature and pressure relief valves for use on storage tanks of hot water supply systems without heater input limitation, hereinafter called "T&P" valves;  b) valves having only pressure relief features for use on storage tanks of hot water supply systems without heater input limitation; and  c) vacuum relief valves.  1.2 A T&P valve operates when the temperature sensing element is at 210 °F (99 °C) or less. A device with a higher operating temperature is not acceptable under this Standard.  1.3 A vacuum relief valve is a single-purpose type.  1.4 All references to psi throughout this Standard are to be considered gage pressures unless otherwise specified.  1.5 Clause 9 contains provisions that are unique to Canada.  1.6 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user shall satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.  Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.  Notes to tables and figures are considered part of the table or figure and may be written as requirements.  Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Previous Editions

Can’t find what you are looking for?

Please contact us at: