API MPMS CH 14.7

API MPMS CH 14.7, 5th Edition: Mass Measurement of Natural Gas Liquids and Other Hydrocarbons (GPA 8182-18)

CDN $152.00

Mass Measurement of Natural Gas Liquids and Other Hydrocarbons (GPA 8182-18)

SKU: c38151d57c10 Category:

Description

This document serves as a reference for the selection, design, installation, operation and maintenance of single-phase dynamic liquid mass measurement systems that operate in the 350 to 688 kg/m3 (0.350 to 0.689 relative density at 60°F) density range. The mass measurement systems within the scope of this document include inferred mass measurement, where volume at flowing conditions is combined with density at similar conditions to result in measured mass, as well as Coriolis mass measurement. Liquids with density below 350 and above 688 kg/m3 (below 0.350 and above 0.689 relative density at 60 °F) and cryogenic fluids (colder than approximately –50 °F) are excluded from the scope of this document, but the principles described herein may apply to such streams. Sampling equipment and techniques are covered including standards for analytical methods used to determine the composition of the sampled product. Equations of state and correlations used to calculate the density of the product

Edition

5

Published Date

2018-02-14

Status

Current

Pages

16

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document serves as a reference for the selection, design, installation, operation and maintenance of single-phase dynamic liquid mass measurement systems that operate in the 350 to 688 kg/m3 (0.350 to 0.689 relative density at 60°F) density range. The mass measurement systems within the scope of this document include inferred mass measurement, where volume at flowing conditions is combined with density at similar conditions to result in measured mass, as well as Coriolis mass measurement. Liquids with density below 350 and above 688 kg/m3 (below 0.350 and above 0.689 relative density at 60 °F) and cryogenic fluids (colder than approximately –50 °F) are excluded from the scope of this document, but the principles described herein may apply to such streams. Sampling equipment and techniques are covered including standards for analytical methods used to determine the composition of the sampled product. Equations of state and correlations used to calculate the density of the product