Search
×
FR

Placeholder headline

This is just a placeholder headline

API STD 521: Guide for Pressure-relieving and Depressuring Systems – Edition 6

$

682

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 653: Tank Inspection, Repair, Alteration, and Reconstruction – Edition 4

$

507

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:19 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series-18: Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z246.2-14 – Emergency preparedness and response for petroleum and natural gas industry systems

$

596

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:22 – Storage of hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z731-09 (R2014) – Emergency Preparedness and Response

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z662:23 – Oil and gas pipeline systems

$

1197

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA Z341 Series:26 – Storage of Hydrocarbons in underground formations

$

878

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA B51:24 Boiler, Pressure Vessel, and Pressure Piping Code

$

389

BUY NOW

API RP 939-C

API RP 939-C: Guidelines for Avoiding Sulfidation (Sulfidic) Corrosion Failures in Oil Refineries

CDN $313.00

This publication was last reviewed and confirmed in 2024.

SKU: 8a861522c127 Category:

Description

This recommended practice (RP) is applicable to hydrocarbon process streams with sulfur-containing compounds, without the presence of hydrogen, which operate at temperatures above approximately 500 °F (260 °C) up to about 1000 °F (540 °C). There is considerable debate in the industry as to the correct threshold temperature for hydrogen free sulfidation and in a change in this Edition, the API 571 threshold of 500 °F (260 °C) is adopted herein. Experience has shown that little significant corrosion will occur at operating temperatures below 500 °F (260 °C) for hydrogen free sulfidation services without the influence of naphthenic acid corrosion. Mercaptan corrosion, particularly in condensate service, has been reported below this temperature, but is not explicitly covered in the 2nd Edition of RP 939-C. For hydrogen containing services, the threshold temperature is set at 450 °F (230 °C). A lower threshold limit for sulfur content is not provided because significant corrosion has occu

Edition

2

Published Date

2019-01-10

Status

Reaffirmed

Pages

59

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This recommended practice (RP) is applicable to hydrocarbon process streams with sulfur-containing compounds, without the presence of hydrogen, which operate at temperatures above approximately 500 °F (260 °C) up to about 1000 °F (540 °C). There is considerable debate in the industry as to the correct threshold temperature for hydrogen free sulfidation and in a change in this Edition, the API 571 threshold of 500 °F (260 °C) is adopted herein. Experience has shown that little significant corrosion will occur at operating temperatures below 500 °F (260 °C) for hydrogen free sulfidation services without the influence of naphthenic acid corrosion. Mercaptan corrosion, particularly in condensate service, has been reported below this temperature, but is not explicitly covered in the 2nd Edition of RP 939-C. For hydrogen containing services, the threshold temperature is set at 450 °F (230 °C). A lower threshold limit for sulfur content is not provided because significant corrosion has occu

Previous Editions

Can’t find what you are looking for?

Please contact us at: