Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

ASSE 1016-2017/ASME A112.1016-2017/CSA B125.16:17 (R2026)

ASSE 1016-2017/ASME A112.1016-2017/CSA B125.16:17 (R2026) – Performance requirements for automatic compensating valves for individual showers and tub/shower combinations

CDN $189.00

Performance requirements for automatic compensating valves for individual showers and tub/shower combinations

Description

Preface This is the second edition of ASSE 1016/ASME A112.1016/CSA B125.16, Performance requirements for automatic compensating valves for individual showers and tub/shower combinations . It supersedes the previous edition published in 2011. This Standard is considered suitable for use with conformity assessment within the stated scope of the Standard. This Standard was prepared by the ASSE/ASME/CSA Harmonization Task Group on Plumbing Fittings, under the jurisdiction of the ASME A112 Main Committee, the ASSE Product Standards Committee, and the CSA Technical Committee on Plumbing Fittings. The CSA Technical Committee operates under the jurisdiction of the CSA Strategic Steering Committee on Construction and Civil Infrastructure. This Standard will be submitted for formal approval by the ASME Standards Committee on Plumbing Materials and Equipment, the ASSE Product Standards Committee and the CSA Technical Committee. This Standard was approved as an American National Standard by the American National Standards Institute on January 6, 2017. Scope 1.1 This Standard applies to automatic compensating valves intended to be installed at the point of use, where the user has access to flow or final temperature controls, and where no further mixing occurs downstream of the device. Note: In this Standard, automatic compensating valves are also referred to as devices. 1.2 This Standard covers automatic compensating valves intended to control the water temperature to wall or ceiling mounted a) hand-held showers; b) shower heads; c) body sprays either in individual shower or tub/shower combination fittings; and d) tub spouts when part of tub/shower combination fittings. 1.3 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.4 SI units are the units of record in Canada. In this Standard the inch/pound units are shown in parentheses. The values stated in each measurement system are equivalent in application; however, each system is to be used independently. Combining values from the two measurement systems can result in non- conformance with this Standard. All references to gallons are to U.S. gallons.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

45

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the second edition of ASSE 1016/ASME A112.1016/CSA B125.16, Performance requirements for automatic compensating valves for individual showers and tub/shower combinations . It supersedes the previous edition published in 2011. This Standard is considered suitable for use with conformity assessment within the stated scope of the Standard. This Standard was prepared by the ASSE/ASME/CSA Harmonization Task Group on Plumbing Fittings, under the jurisdiction of the ASME A112 Main Committee, the ASSE Product Standards Committee, and the CSA Technical Committee on Plumbing Fittings. The CSA Technical Committee operates under the jurisdiction of the CSA Strategic Steering Committee on Construction and Civil Infrastructure. This Standard will be submitted for formal approval by the ASME Standards Committee on Plumbing Materials and Equipment, the ASSE Product Standards Committee and the CSA Technical Committee. This Standard was approved as an American National Standard by the American National Standards Institute on January 6, 2017. Scope 1.1 This Standard applies to automatic compensating valves intended to be installed at the point of use, where the user has access to flow or final temperature controls, and where no further mixing occurs downstream of the device. Note: In this Standard, automatic compensating valves are also referred to as devices. 1.2 This Standard covers automatic compensating valves intended to control the water temperature to wall or ceiling mounted a) hand-held showers; b) shower heads; c) body sprays either in individual shower or tub/shower combination fittings; and d) tub spouts when part of tub/shower combination fittings. 1.3 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.4 SI units are the units of record in Canada. In this Standard the inch/pound units are shown in parentheses. The values stated in each measurement system are equivalent in application; however, each system is to be used independently. Combining values from the two measurement systems can result in non- conformance with this Standard. All references to gallons are to U.S. gallons.

Previous Editions

Can’t find what you are looking for?

Please contact us at: