
C22.2 NO. 14-18 (R2022)
C22.2 NO. 14-18 (R2022) – Industrial control equipment
CDN $455.00
Industrial control equipment
Description
Preface This is the thirteenth edition of CSA C22.2 No. 14, Industrial control equipment , one of a series of Standards issued by the Canadian Standards Association under Part II of the Canadian Electrical Code. It supersedes the previous editions, published in 2013, 2010, 2005, 1995, 1991, 1987, 1985, 1973, 1966, 1953, 1942, and 1935. This edition incorporates numerous revisions. The major revisions include adding a section for the construction requirements of accessible circuits, a section for the construction requirements of wireless controls and a section for leakage current testing. In addition, numerous tables were updated, a number of new definitions introduced, a new figure added and a host of other minor updates made to various clauses throughout. The requirements of CSA LTR M-003 have also been incorporated in this edition. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Integrated Committee on Industrial Control, under the jurisdiction of the Technical Committee on Industrial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. Scope 1.1 This Standard applies to control and protective devices, and accessory devices, rated at not more than 1500 V, for starting, stopping, regulating, controlling, or protecting electric motors, generators, heating apparatus, or other equipment used to control an industrial process that is intended to be installed and used in non-hazardous locations in accordance with the rules of the Canadian Electrical Code, Part I. Notes: 1) Examples of the industrial control devices covered by this Standard are manual and magnetic starters and controllers; thermal and magnetic overload relays; push-button stations (including selector switches and pilot lights); control circuit switches and relays; float-, flow-, pressure-, and vacuum-operated switches; resistors and rheostats; proximity switches; time-delay relays and switches; resistors and rheostats intended for heating and lighting, including those for motor generator fields; and control devices intended for heating and lighting. 2) The term “control” as used throughout this Standard applies to both starters and controllers. 3) Electrical instruments, such as meters, that can be included as part of control equipment are not covered by this Standard. 1.2 — Deleted 1.3 — Deleted 1.4 This Standard does not apply to equipment covered by other CSA Standards, such as power supplies, programmable logic controllers, assemblies of equipment intended solely for the distribution of power, assemblies for controlling power factor, switches other than manual motor controllers, motor control centres, industrial control panels, and electrical components intended to protect circuits other than motor branch-circuits. 1.4A Certain equipment intended for use with electric elevators, air-conditioning and refrigeration equipment, cranes and hoists, electronic and solid-state control equipment, and “TV”-rated relays, etc., can be subject to additional requirements not included in this Standard. 1.5 The industrial control equipment covered by this Standard is intended for use in an ambient temperature of 0 to 40 °C, unless otherwise marked. 1.6 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
169
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the thirteenth edition of CSA C22.2 No. 14, Industrial control equipment , one of a series of Standards issued by the Canadian Standards Association under Part II of the Canadian Electrical Code. It supersedes the previous editions, published in 2013, 2010, 2005, 1995, 1991, 1987, 1985, 1973, 1966, 1953, 1942, and 1935. This edition incorporates numerous revisions. The major revisions include adding a section for the construction requirements of accessible circuits, a section for the construction requirements of wireless controls and a section for leakage current testing. In addition, numerous tables were updated, a number of new definitions introduced, a new figure added and a host of other minor updates made to various clauses throughout. The requirements of CSA LTR M-003 have also been incorporated in this edition. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Integrated Committee on Industrial Control, under the jurisdiction of the Technical Committee on Industrial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. Scope 1.1 This Standard applies to control and protective devices, and accessory devices, rated at not more than 1500 V, for starting, stopping, regulating, controlling, or protecting electric motors, generators, heating apparatus, or other equipment used to control an industrial process that is intended to be installed and used in non-hazardous locations in accordance with the rules of the Canadian Electrical Code, Part I. Notes: 1) Examples of the industrial control devices covered by this Standard are manual and magnetic starters and controllers; thermal and magnetic overload relays; push-button stations (including selector switches and pilot lights); control circuit switches and relays; float-, flow-, pressure-, and vacuum-operated switches; resistors and rheostats; proximity switches; time-delay relays and switches; resistors and rheostats intended for heating and lighting, including those for motor generator fields; and control devices intended for heating and lighting. 2) The term “control” as used throughout this Standard applies to both starters and controllers. 3) Electrical instruments, such as meters, that can be included as part of control equipment are not covered by this Standard. 1.2 — Deleted 1.3 — Deleted 1.4 This Standard does not apply to equipment covered by other CSA Standards, such as power supplies, programmable logic controllers, assemblies of equipment intended solely for the distribution of power, assemblies for controlling power factor, switches other than manual motor controllers, motor control centres, industrial control panels, and electrical components intended to protect circuits other than motor branch-circuits. 1.4A Certain equipment intended for use with electric elevators, air-conditioning and refrigeration equipment, cranes and hoists, electronic and solid-state control equipment, and “TV”-rated relays, etc., can be subject to additional requirements not included in this Standard. 1.5 The industrial control equipment covered by this Standard is intended for use in an ambient temperature of 0 to 40 °C, unless otherwise marked. 1.6 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA E61959:14 (R2024) – Secondary cells and batteries containing alkaline or other non-acid electrolytes – Mechanical tests for sealed portable secondary cells and batteries (Adopted IEC 61959:2004, first edition, 2004-01, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide – Essais mécaniques pour accumulateurs portables étanches (norme CEI 61959:2004 adoptée, première édition, 2004-01, avec exigences propres au Canada)
CDN $56.00 Add to cart -

CSA C22.3 NO. 5.1:93 (R2022) – Recommended practices for electrical protection – Electric contact between overhead supply and communication lines
CDN $149.00 Add to cart -

CSA E61951-2:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 2: Nickel-metal hydride (Adopted IEC 61951-2:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 2 : Nickel-métal hydrure (norme IEC 61951-2:2017 adoptée, quatrième édition, 2017-03, avec exigences propres au Canada)
CDN $527.00 Add to cart -

CAN/CSA-E61558-1:12 (R2022) – Safety of power transformers, power supplies, reactors and similar products – Part 1: General requirements and tests (Adopted IEC 61558- 1:1997 + A1:1998, edition 2.1, 2009-04 with Canadian deviations) | Sécurité des transformateurs, alimentations, bobines d’inductance et produits analogues – Partie 1: Exigences générales et essais (norme CEI 61558-1:1997 + A1:1998 adoptée, édition 2.1, 2009-04 avec exigences propres au Canada)
CDN $630.00 Add to cart







