C22.2 NO. 144.1-16 (R2025)
C22.2 NO. 144.1-16 (R2025) – Ground-fault circuit-interrupters (Tri-national standard with UL 943 and NMX-J-520-ANCE)
CDN $943.00
Ground-fault circuit-interrupters (Tri-national standard with UL 943 and NMX-J-520-ANCE)
Description
Preface This is the harmonized ANCE, CSA Group, and ULSE standard for Ground-Fault Circuit-Interrupters . It is the third edition of NMX-J-520-ANCE, the second edition of CSA C22.2 No. 144.1, and the fifth edition of UL 943. This harmonized standard has been jointly revised on August 25, 2025. For this purpose, CSA Group and ULSE are issuing revision pages dated August 25, 2025, and ANCE is issuing a new edition dated August 25, 2025. This harmonized Standard was prepared by the Association of Standardization and Certification (ANCE), CSA Group, and ULSE. The efforts and support of the CANENA Technical Harmonization Subcommittee 23E, Ground-Fault Circuit-Interrupters, are gratefully acknowledged. This standard is considered suitable for use for conformity assessment within the stated scope of the standard. The present Mexican standard was developed by the CT 23 Accesorios Electricos from the Comite de Normalizacion de la Asociacion de Normalizacion y Certificacion, A.C., CONANCE, with the collaboration of the ground fault circuit interrupters manufacturers and users. This Standard was reviewed by the CSA Subcommittee on Ground-Fault Circuit-Interrupters, under the jurisdiction of the CSA Technical Committee on Industrial Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the CSA Technical Committee. Scope 1.1 This Standard applies to Class A, single- and three-phase, ground-fault circuit-interrupters intended for protection of personnel, for use only in grounded neutral systems in accordance with the National Electrical Code (NEC), ANSI/NFPA 70, the Canadian Electrical Code, Part I, and Electrical Installations (Use), NOM-001-SEDE. These devices are intended for use on alternating current (AC) circuits of 120 V, 208Y/120 V, 120/240 V, 127 V, or 220Y/127 V, 60 Hz circuits. Note – In Canada, the text “intended for protection of personnel” is excluded. 1.2 These requirements do not cover ground-fault circuit-interrupters intended for use in circuits served by a transformer having windings wholly insulated from each other. 1.3 This Standard applies to all Class A ground-fault circuit-interrupters. These Class A GFCIs are permitted to be integrated into other devices, in which case, besides complying with this Standard, these devices are to comply with the corresponding applicable Standard for the device in question. 1.4 This Standard includes minimum requirements for the function, construction, performance, and markings of ground-fault circuit-interrupters included in the scope. 1.5 This Standard is intended to cover only Class A GFCI devices. 1.6 This Standard also covers GFCIs of the self contained type that are intended for installation in a counter, such as would be suitable for installation in a kitchen or bathroom counter top.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
116
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the harmonized ANCE, CSA Group, and ULSE standard for Ground-Fault Circuit-Interrupters . It is the third edition of NMX-J-520-ANCE, the second edition of CSA C22.2 No. 144.1, and the fifth edition of UL 943. This harmonized standard has been jointly revised on August 25, 2025. For this purpose, CSA Group and ULSE are issuing revision pages dated August 25, 2025, and ANCE is issuing a new edition dated August 25, 2025. This harmonized Standard was prepared by the Association of Standardization and Certification (ANCE), CSA Group, and ULSE. The efforts and support of the CANENA Technical Harmonization Subcommittee 23E, Ground-Fault Circuit-Interrupters, are gratefully acknowledged. This standard is considered suitable for use for conformity assessment within the stated scope of the standard. The present Mexican standard was developed by the CT 23 Accesorios Electricos from the Comite de Normalizacion de la Asociacion de Normalizacion y Certificacion, A.C., CONANCE, with the collaboration of the ground fault circuit interrupters manufacturers and users. This Standard was reviewed by the CSA Subcommittee on Ground-Fault Circuit-Interrupters, under the jurisdiction of the CSA Technical Committee on Industrial Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the CSA Technical Committee. Scope 1.1 This Standard applies to Class A, single- and three-phase, ground-fault circuit-interrupters intended for protection of personnel, for use only in grounded neutral systems in accordance with the National Electrical Code (NEC), ANSI/NFPA 70, the Canadian Electrical Code, Part I, and Electrical Installations (Use), NOM-001-SEDE. These devices are intended for use on alternating current (AC) circuits of 120 V, 208Y/120 V, 120/240 V, 127 V, or 220Y/127 V, 60 Hz circuits. Note - In Canada, the text "intended for protection of personnel" is excluded. 1.2 These requirements do not cover ground-fault circuit-interrupters intended for use in circuits served by a transformer having windings wholly insulated from each other. 1.3 This Standard applies to all Class A ground-fault circuit-interrupters. These Class A GFCIs are permitted to be integrated into other devices, in which case, besides complying with this Standard, these devices are to comply with the corresponding applicable Standard for the device in question. 1.4 This Standard includes minimum requirements for the function, construction, performance, and markings of ground-fault circuit-interrupters included in the scope. 1.5 This Standard is intended to cover only Class A GFCI devices. 1.6 This Standard also covers GFCIs of the self contained type that are intended for installation in a counter, such as would be suitable for installation in a kitchen or bathroom counter top.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA E61558-2-13:25 – Safety of transformers, reactors, power supply units and combinations thereof — Part 2-13: Particular requirements and tests for auto-transformers and power supply units incorporating auto-transformers for general applications (Adopted IEC 61558-2-13:2022, third edition, 2022-10, with Canadian deviations) | Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et combinaisons de ces éléments — Partie 2-13 : Exigences particulières et essais pour les autotransformateurs et les blocs d’alimentation qui incorporent des autotransformateurs pour applications d’ordre général (norme IEC 61558-2-13:2022 adoptée, troisième édition, 2022-10, avec exigences propres au Canada)
CDN $205.00 Add to cart -

CSA E61951-1:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 1: Nickel-cadmium (Adopted IEC 61951:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 1 : Nickel-cadmium (norme IEC 61951-1:2017 adoptée, quatrième édition, 2017-03), avec exigences propres au Canada)
CDN $527.00 Add to cart -

CSA E61347-2-3:23 – Lamp control gear — Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps (Adopted IEC 61347-2-3:2011, edition 2:2011 consolidated with amendment 1:2016, with Canadian deviations) | Appareillages de lampes — Partie 2-3 : Exigences particulières pour les appareillages électroniques alimentés en courant alternatif et/ou en courant continu pour lampes fluorescentes (norme IEC 61347-2-3:2011 adoptée, édition 2:2011 consolidée par l’amendement 1:2016, avec exigences propres au Canada)
CDN $620.00 Add to cart -

IEEE 844.2-2017/CSA C293.2:17 (R2022) – Skin effect trace heating of pipelines, vessels, equipment, and structures—Application guide for design, installation, testing, commissioning, and maintenance
CDN $158.00 Add to cart