
C22.2 NO. 174-18 (R2022)
C22.2 NO. 174-18 (R2022) – Cables and cable glands for use in hazardous locations
CDN $158.00
Cables and cable glands for use in hazardous locations
Description
Preface This is the third edition of CSA C22.2 No. 174, Cables and cable glands for use in hazardous locations, one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. It supersedes the previous editions published in 1984 and 1981. The major changes in this edition are as follows: a) removal of requirements that are addressed in other standards; b) addition of supplementary jacket testing for unarmoured cables to ensure robustness during installation; and c) reorganization for clarity and consistency with current practice. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Cables and Cable Glands for Hazardous Locations Task Force, under the jurisdiction of the Integrated Committee on Hazardous Location Products, the Technical Committee on Industrial Products, and the Strategic Steering Committee on Requirements for Electrical Safety. This Standard has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 General This Standard applies to a) cables for use in hazardous locations in accordance with CSA C22.1, Canadian Electrical Code, Part I (CE Code, Part I); and b) cable glands for use in Class I, Division 1 or Class II, Division 1 hazardous locations in accordance with the CE Code, Part I. The requirements in this Standard are in addition to the basic electrical requirements applicable to such cables and cable glands for use in locations other than hazardous locations. Notes: 1) Cable glands may be approved with an Ex method of protection according to the CAN/CSA-C22.2 No. 60079 series of standards without demonstrating compliance to this Standard. 2) Cable glands for use in Class I, Division 2 or Class II, Division 2 are not covered by this Standard because their requirements are dictated by the equipment to which they are connected. For example, an explosion-proof box installed in a Class I, Division 2 location requires the use of a Class I, Division 1 cable gland. 1.2 Terminology In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.3 Units of measure The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
32
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the third edition of CSA C22.2 No. 174, Cables and cable glands for use in hazardous locations, one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. It supersedes the previous editions published in 1984 and 1981. The major changes in this edition are as follows: a) removal of requirements that are addressed in other standards; b) addition of supplementary jacket testing for unarmoured cables to ensure robustness during installation; and c) reorganization for clarity and consistency with current practice. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Cables and Cable Glands for Hazardous Locations Task Force, under the jurisdiction of the Integrated Committee on Hazardous Location Products, the Technical Committee on Industrial Products, and the Strategic Steering Committee on Requirements for Electrical Safety. This Standard has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 General This Standard applies to a) cables for use in hazardous locations in accordance with CSA C22.1, Canadian Electrical Code, Part I (CE Code, Part I); and b) cable glands for use in Class I, Division 1 or Class II, Division 1 hazardous locations in accordance with the CE Code, Part I. The requirements in this Standard are in addition to the basic electrical requirements applicable to such cables and cable glands for use in locations other than hazardous locations. Notes: 1) Cable glands may be approved with an Ex method of protection according to the CAN/CSA-C22.2 No. 60079 series of standards without demonstrating compliance to this Standard. 2) Cable glands for use in Class I, Division 2 or Class II, Division 2 are not covered by this Standard because their requirements are dictated by the equipment to which they are connected. For example, an explosion-proof box installed in a Class I, Division 2 location requires the use of a Class I, Division 1 cable gland. 1.2 Terminology In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.3 Units of measure The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CAN/CSA-E61558-1:12 (R2022) – Safety of power transformers, power supplies, reactors and similar products – Part 1: General requirements and tests (Adopted IEC 61558- 1:1997 + A1:1998, edition 2.1, 2009-04 with Canadian deviations) | Sécurité des transformateurs, alimentations, bobines d’inductance et produits analogues – Partie 1: Exigences générales et essais (norme CEI 61558-1:1997 + A1:1998 adoptée, édition 2.1, 2009-04 avec exigences propres au Canada)
CDN $630.00 Add to cart -

IEEE 844.3-2019/CSA C22.2 NO. 293.3:19 (R2024) – Impedance heating of pipelines and equipment—General, testing, marking, and documentation requirements
CDN $174.00 Add to cart -

CSA E61558-2-5:25 – Safety of transformers, reactors, power supply units and combinations thereof — Part 2-5: Particular requirements and tests for transformers for shavers, power supply units for shavers and shaver supply units (Adopted IEC 61558-2-5:2024, third edition, 2024-08, with Canadian deviations) | Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et combinaisons de ces éléments — Partie 2-5 : Exigences particulières et essais pour les transformateurs pour rasoirs, les blocs d’alimentation incorporant un transformateur pour rasoir et les blocs d’alimentation pour rasoirs (norme IEC 61558-2-5:2024 adoptée, troisième édition, 2024-08, avec exigences propres au Canada)
CDN $299.00 Add to cart -

IEEE 844.4-2019/CSA C293.4:19 (R2024) – Impedance heating of pipelines and equipment—Application guide for design, installation, testing, commissioning, and maintenance
CDN $174.00 Add to cart







