Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

C22.2 NO. 182.3-16 (R2026)

C22.2 NO. 182.3-16 (R2026) – Special use attachment plugs, receptacles and connectors

CDN $164.00

Special use attachment plugs, receptacles and connectors

SKU: 2424514 Categories: ,

Description

Preface This is the second edition of CSA C22.2 No. 182.3, Special use attachment plugs, receptacles and connectors. It supersedes the previous edition published in 1987. It is one of a series of Standards issued under Part II of the Canadian Electrical Code.  For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of the latest edition of CAN/CSA-C22.2 No. 0.  This new edition incorporates requirements for connectors using IDC terminations.  Scope 1.1 This Standard applies to plugs, receptacles, power inlets and outlets, connectors, and similar wiring devices intended for use in electronic and electrical applications in accordance with the Canadian Electrical Code, Part I. The types covered are as follows (see Figure 3):  a) Type 0 rated up to 8.3 A and up to 30 V rms (42 V peak) b) Type 1A rated up to 8.3 A and from 30 V to 600 V ac or dc, or both c) Type 1B rated from 8.3 A up to 200 A and up to 30 V rms (42 V peak) d) Type 2 rated from 8.3 A up to 31 A and from 30 V to 600 V ac or dc, or both e) Type 3 rated from 31 A up to 200 A and from 30 V to 600 V ac or dc, or both f) Type 4 rated from more than 200 A up to and including 1000 A, and up to 600 V ac or dc g) Type 5 rated less than 31 A and from over 600 V up to and including 6000 V ac or dc, or both Note: As there is a great variety of applications for products covered by this Standard, their use should be evaluated with the design and construction of the end use application and cannot be solely judged by the requirements of this Standard.  1.2 This Standard does not apply to a) appliance plugs covered in CSA C22.2 No. 57 b) general use receptacles, attachment plugs, and similar wiring devices covered in CSA C22.2 No. 42  c) industrial type, special use attachment plugs, receptacles, equipment power inlets and outlets, and connectors covered in CSA C22.2 No. 182.1 d) industrial locking type attachment plugs, receptacles, and connectors covered in CSA C22.2 No. 182.2 1.3 Attachment plugs, receptacles, and similar wiring devices intended for use in hazardous locations covered in this standard shall also meet the requirements of CSA C22.2 No. 159 as applicable.  1.4 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard.  Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.  Notes to tables and figures are considered part of the table or figure and may be written as requirements.  Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

53

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the second edition of CSA C22.2 No. 182.3, Special use attachment plugs, receptacles and connectors. It supersedes the previous edition published in 1987. It is one of a series of Standards issued under Part II of the Canadian Electrical Code.  For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of the latest edition of CAN/CSA-C22.2 No. 0.  This new edition incorporates requirements for connectors using IDC terminations.  Scope 1.1 This Standard applies to plugs, receptacles, power inlets and outlets, connectors, and similar wiring devices intended for use in electronic and electrical applications in accordance with the Canadian Electrical Code, Part I. The types covered are as follows (see Figure 3):  a) Type 0 rated up to 8.3 A and up to 30 V rms (42 V peak) b) Type 1A rated up to 8.3 A and from 30 V to 600 V ac or dc, or both c) Type 1B rated from 8.3 A up to 200 A and up to 30 V rms (42 V peak) d) Type 2 rated from 8.3 A up to 31 A and from 30 V to 600 V ac or dc, or both e) Type 3 rated from 31 A up to 200 A and from 30 V to 600 V ac or dc, or both f) Type 4 rated from more than 200 A up to and including 1000 A, and up to 600 V ac or dc g) Type 5 rated less than 31 A and from over 600 V up to and including 6000 V ac or dc, or both Note: As there is a great variety of applications for products covered by this Standard, their use should be evaluated with the design and construction of the end use application and cannot be solely judged by the requirements of this Standard.  1.2 This Standard does not apply to a) appliance plugs covered in CSA C22.2 No. 57 b) general use receptacles, attachment plugs, and similar wiring devices covered in CSA C22.2 No. 42  c) industrial type, special use attachment plugs, receptacles, equipment power inlets and outlets, and connectors covered in CSA C22.2 No. 182.1 d) industrial locking type attachment plugs, receptacles, and connectors covered in CSA C22.2 No. 182.2 1.3 Attachment plugs, receptacles, and similar wiring devices intended for use in hazardous locations covered in this standard shall also meet the requirements of CSA C22.2 No. 159 as applicable.  1.4 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard.  Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.  Notes to tables and figures are considered part of the table or figure and may be written as requirements.  Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Previous Editions

Can’t find what you are looking for?

Please contact us at: