Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

C22.2 NO. 46-13 (R2022)

C22.2 NO. 46-13 (R2022) – Electric air-heaters

CDN $148.00

Electric air-heaters

SKU: 2421945 Categories: ,

Description

Preface This is the ninth edition of CSA C22.2 No. 46, Electric air heaters , one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. It supersedes previous editions published in 1988, 1981, 1980, 1971, 1966, 1959, 1942, and 1938. This edition mainly serves to incorporate Updates 1 through 4 of the 1988 edition, modify the scope to clarify the products not covered by this Standard, and to update the reference publications. For general information on the Standards of the Canadian Electrical Code, Part II, see the preface of CAN/CSA-C22.2 No. 0. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Electric Air-Heaters, under the jurisdiction of the Technical Committee on Consumer and Commercial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. Scope 1.1 This Standard applies to air heaters intended for use on nominal system voltages of 600 V or less and designed to be used in accordance with the Canadian Electrical Code, Part I. 1.2 This Standard applies to permanently connected and cord-connected air heaters for household, commercial, and industrial use in non-hazardous locations. 1.3 The term “air heater” includes the following types: (a) convection; (b) forced air; (c) radiation; (d) ceiling types, alone or in combination with lighting or ventilating components, or both; (e) liquid-filled radiator; and (f) combinations of (a), (b), or (c). Note: For convenience, except where distinctions are necessary, portable and stationary air heaters are referred to throughout this Standard as “heaters”. 1.4 This Standard does not apply to (a) unit heaters involving only steam or hot-water heating with an electric air circulator; (b) electric duct heaters, as covered in CSA C22.2 No. 155; (c) central electric warm-air furnaces, as covered in CSA C22.2 No. 236; and (d) radiant space-heating panels (i) installed below the subfloor; (ii) mounted behind drywall or above plaster ceilings; (iii) mounted above a suspended ceiling grid system; (iv) forming all or part of a finished ceiling system; and (v) dropped into a ceiling system in its final finished form. Requirements for cord-connected double-insulated electric air heaters are specified in Clause 8 of this Standard. 1.5 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

68

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the ninth edition of CSA C22.2 No. 46, Electric air heaters , one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. It supersedes previous editions published in 1988, 1981, 1980, 1971, 1966, 1959, 1942, and 1938. This edition mainly serves to incorporate Updates 1 through 4 of the 1988 edition, modify the scope to clarify the products not covered by this Standard, and to update the reference publications. For general information on the Standards of the Canadian Electrical Code, Part II, see the preface of CAN/CSA-C22.2 No. 0. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Electric Air-Heaters, under the jurisdiction of the Technical Committee on Consumer and Commercial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. Scope 1.1 This Standard applies to air heaters intended for use on nominal system voltages of 600 V or less and designed to be used in accordance with the Canadian Electrical Code, Part I. 1.2 This Standard applies to permanently connected and cord-connected air heaters for household, commercial, and industrial use in non-hazardous locations. 1.3 The term "air heater" includes the following types: (a) convection; (b) forced air; (c) radiation; (d) ceiling types, alone or in combination with lighting or ventilating components, or both; (e) liquid-filled radiator; and (f) combinations of (a), (b), or (c). Note: For convenience, except where distinctions are necessary, portable and stationary air heaters are referred to throughout this Standard as "heaters". 1.4 This Standard does not apply to (a) unit heaters involving only steam or hot-water heating with an electric air circulator; (b) electric duct heaters, as covered in CSA C22.2 No. 155; (c) central electric warm-air furnaces, as covered in CSA C22.2 No. 236; and (d) radiant space-heating panels (i) installed below the subfloor; (ii) mounted behind drywall or above plaster ceilings; (iii) mounted above a suspended ceiling grid system; (iv) forming all or part of a finished ceiling system; and (v) dropped into a ceiling system in its final finished form. Requirements for cord-connected double-insulated electric air heaters are specified in Clause 8 of this Standard. 1.5 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

Previous Editions

Can’t find what you are looking for?

Please contact us at: