Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

C22.2 NO. 66.1-06 (R2025)

C22.2 NO. 66.1-06 (R2025) – Low Voltage Transformers – Part 1: General Requirements (Bi-National standard, with UL 5085-1)

CDN $493.00

Low Voltage Transformers – Part 1: General Requirements (Bi-National standard, with UL 5085-1)

SKU: 2418011 Categories: ,

Description

Preface This is the common CSA and UL standard for low voltage transformers. It is the first edition of CSA C22.2 No. 66.1 and the first edition of UL 5085-1. This edition of CSA C22.2 No. 66.1 supersedes the requirements of CSA C22.2 No. 66 published in 1988. This edition of UL 5085-1 supersedes the Twelfth edition of UL 506 published in 2000 and the Fourth edition of UL 1585 published in 1998. This common standard was prepared by a Technical Harmonization Committee comprised of members from the Canadian Standards Association (CSA), Underwriters Laboratories Inc. (UL), and representatives of the low voltage transformer manufacturing industry. The efforts and support of members of the Technical Harmonization Committee are gratefully acknowledged. This standard was reviewed by the CSA Subcommittee on C22.2 No. 66, under the jurisdiction of the CSA Technical Committee on Industrial Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the CSA Technical Committee. This Standard has been approved by the American National Standards Institute (ANSI) as an American National Standard. Scope 1.1 These requirements cover the following types of transformers: a) Air-cooled transformers and reactors for general use; b) General purpose autotransformers; c) Ferroresonant transformers; d) Class 2 and Class 3 transformers (which are evaluated in accordance with Part 3); e) Cord-connected transformers (which are evaluated in accordance with Part 2); f) Transformers incorporating overcurrent or over-temperature protective devices, transient voltage surge protectors, or capacitors; and g) Permanently-connected transformers. 1.2 These transformers are intended to be used in accordance with the National Electrical Code, ANSI/NFPA 70, or CSA C22.1, the Canadian Electrical Code, Part I. The Canadian Electrical Code defines low voltage as any voltage from 31 to 750 V inclusive and high voltage as any voltage above 750 V. The National Electrical Code, ANSI/NFPA 70, defines low voltage as any voltage up to 600 V, nominal. Therefore, low voltage transformers intended for use in Canada may be rated above 600 V up to 750 V. Low voltage transformers intended for use in the United States are rated up to 600 V. Where information in clauses and tables in this standard reference voltage ranges, the limit of 600 V applies in the United States, while the limit of 750 V applies in Canada. 1.3 The standard does not cover the following transformers: a) Direct plug-in types; b) Neon; c) Liquid-immersed; d) Variable voltage (Variac); e) Low voltage landscape; f) Swimming pool and spa: g) Ignition; h) High intensity lighting; i) Toy; j) Fluorescent lamp types; k) Transformers for welders; l) Distribution; m) Transformers intended for use in the United States with a nominal primary rating of more than 600 V; n) Transformers incorporating rectifying or waveshaping circuitry; o) Transformers for use with radio- and television-type appliances; p) Transformers intended for use in the United States having overvoltage taps rated over 660 V; q) Autotransformers used in industrial control equipment, which are evaluated in accordance with the requirements of the Standard for Industrial Control Equipment, UL 508, or CSA C22.2 No. 14, Industrial Control Equipment; and r) Other special types of transformers covered in requirements for other electrical devices or appliances. 1.4 Part 1, as well as Part 2 and Part 3, establish the characteristics, construction, operating conditions, markings, and test conditions for each type of transformer. 1.5 The requirements in this standard may be modified by requirements in an end product standard if a transformer is intended for use only as a component in other equipment.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

114

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the common CSA and UL standard for low voltage transformers. It is the first edition of CSA C22.2 No. 66.1 and the first edition of UL 5085-1. This edition of CSA C22.2 No. 66.1 supersedes the requirements of CSA C22.2 No. 66 published in 1988. This edition of UL 5085-1 supersedes the Twelfth edition of UL 506 published in 2000 and the Fourth edition of UL 1585 published in 1998. This common standard was prepared by a Technical Harmonization Committee comprised of members from the Canadian Standards Association (CSA), Underwriters Laboratories Inc. (UL), and representatives of the low voltage transformer manufacturing industry. The efforts and support of members of the Technical Harmonization Committee are gratefully acknowledged. This standard was reviewed by the CSA Subcommittee on C22.2 No. 66, under the jurisdiction of the CSA Technical Committee on Industrial Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the CSA Technical Committee. This Standard has been approved by the American National Standards Institute (ANSI) as an American National Standard. Scope 1.1 These requirements cover the following types of transformers: a) Air-cooled transformers and reactors for general use; b) General purpose autotransformers; c) Ferroresonant transformers; d) Class 2 and Class 3 transformers (which are evaluated in accordance with Part 3); e) Cord-connected transformers (which are evaluated in accordance with Part 2); f) Transformers incorporating overcurrent or over-temperature protective devices, transient voltage surge protectors, or capacitors; and g) Permanently-connected transformers. 1.2 These transformers are intended to be used in accordance with the National Electrical Code, ANSI/NFPA 70, or CSA C22.1, the Canadian Electrical Code, Part I. The Canadian Electrical Code defines low voltage as any voltage from 31 to 750 V inclusive and high voltage as any voltage above 750 V. The National Electrical Code, ANSI/NFPA 70, defines low voltage as any voltage up to 600 V, nominal. Therefore, low voltage transformers intended for use in Canada may be rated above 600 V up to 750 V. Low voltage transformers intended for use in the United States are rated up to 600 V. Where information in clauses and tables in this standard reference voltage ranges, the limit of 600 V applies in the United States, while the limit of 750 V applies in Canada. 1.3 The standard does not cover the following transformers: a) Direct plug-in types; b) Neon; c) Liquid-immersed; d) Variable voltage (Variac); e) Low voltage landscape; f) Swimming pool and spa: g) Ignition; h) High intensity lighting; i) Toy; j) Fluorescent lamp types; k) Transformers for welders; l) Distribution; m) Transformers intended for use in the United States with a nominal primary rating of more than 600 V; n) Transformers incorporating rectifying or waveshaping circuitry; o) Transformers for use with radio- and television-type appliances; p) Transformers intended for use in the United States having overvoltage taps rated over 660 V; q) Autotransformers used in industrial control equipment, which are evaluated in accordance with the requirements of the Standard for Industrial Control Equipment, UL 508, or CSA C22.2 No. 14, Industrial Control Equipment; and r) Other special types of transformers covered in requirements for other electrical devices or appliances. 1.4 Part 1, as well as Part 2 and Part 3, establish the characteristics, construction, operating conditions, markings, and test conditions for each type of transformer. 1.5 The requirements in this standard may be modified by requirements in an end product standard if a transformer is intended for use only as a component in other equipment.

Previous Editions

Can’t find what you are looking for?

Please contact us at: