Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CAN/CSA-A23.3-04 (R2010)

CAN/CSA-A23.3-04 (R2010) – Design of concrete structures

CDN $394.00

Design of concrete structures

SKU: 2417424 Categories: ,

Description

Preface This is the fifth edition of CSA A23.3, Design of concrete structures. It supersedes the previous editions published in 1994, 1984, 1977 (metric) and 1973 (imperial), and 1959. This Standard is intended for use in the design of concrete structures for buildings in conjunction with CSA A23.1-04/A23.2-04, Concrete materials and methods of concrete construction/Methods of test and standard practices for concrete, and CSA A23.4, Precast concrete – Materials and construction (under preparation). Scope 1.1 General This Standard specifies requirements, in accordance with the National Building Code of Canada, for the design and strength evaluation of (a) structures of reinforced and prestressed concrete; (b) plain concrete elements; and (c) special structures such as parking structures, arches, tanks, reservoirs, bins and silos, towers, water towers, blast-resistant structures, and chimneys. Note: Special requirements for parking structures are specified in CAN/CSA-S413. 1.2 Fire resistance This Standard requires designs to be carried out in accordance with the fire resistance requirements of the applicable building code (see Clause 8.1.2). 1.3 Alternative design procedures Designs that use procedures which are not covered by this Standard but are carried out by a person qualified in the methods applied and provide a level of safety and performance equivalent to designs complying with this Standard are acceptable if carried out by one of the following methods: (a) analysis based on generally established theory; (b) evaluation of a full-scale structure or a prototype by a loading test; or (c) studies of model analogues. 1.4 Terminology In CSA Standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; “may” is used to express an option or that which is permissible within the limits of the standard; and “can” is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.5 Units of measurement Equations appearing in this Standard are compatible with the following units: (a) area: mm2 (square millimetres); (b) force: N (newtons); (c) length: mm (millimetres); (d) moment: N.mm (newton millimetres); and (e) stress: MPa (megapascals). Whenever the square root of the concrete strength is determined, the concrete strength and the square root of the concrete strength are both expressed in megapascals. Other dimensionally consistent combinations of units may be used, provided that appropriate adjustments are made to constants in non-homogeneous equations. Note: Some examples of non-homogeneous equations are found in Clauses 12.2.2 and 12.8.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

352

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the fifth edition of CSA A23.3, Design of concrete structures. It supersedes the previous editions published in 1994, 1984, 1977 (metric) and 1973 (imperial), and 1959. This Standard is intended for use in the design of concrete structures for buildings in conjunction with CSA A23.1-04/A23.2-04, Concrete materials and methods of concrete construction/Methods of test and standard practices for concrete, and CSA A23.4, Precast concrete - Materials and construction (under preparation). Scope 1.1 General This Standard specifies requirements, in accordance with the National Building Code of Canada, for the design and strength evaluation of (a) structures of reinforced and prestressed concrete; (b) plain concrete elements; and (c) special structures such as parking structures, arches, tanks, reservoirs, bins and silos, towers, water towers, blast-resistant structures, and chimneys. Note: Special requirements for parking structures are specified in CAN/CSA-S413. 1.2 Fire resistance This Standard requires designs to be carried out in accordance with the fire resistance requirements of the applicable building code (see Clause 8.1.2). 1.3 Alternative design procedures Designs that use procedures which are not covered by this Standard but are carried out by a person qualified in the methods applied and provide a level of safety and performance equivalent to designs complying with this Standard are acceptable if carried out by one of the following methods: (a) analysis based on generally established theory; (b) evaluation of a full-scale structure or a prototype by a loading test; or (c) studies of model analogues. 1.4 Terminology In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the standard; and "can" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.5 Units of measurement Equations appearing in this Standard are compatible with the following units: (a) area: mm2 (square millimetres); (b) force: N (newtons); (c) length: mm (millimetres); (d) moment: N.mm (newton millimetres); and (e) stress: MPa (megapascals). Whenever the square root of the concrete strength is determined, the concrete strength and the square root of the concrete strength are both expressed in megapascals. Other dimensionally consistent combinations of units may be used, provided that appropriate adjustments are made to constants in non-homogeneous equations. Note: Some examples of non-homogeneous equations are found in Clauses 12.2.2 and 12.8.

Previous Editions

Can’t find what you are looking for?

Please contact us at: