CAN/CSA-C61000-2-2:04 (R2023)
CAN/CSA-C61000-2-2:04 (R2023) – Electromagnetic compatibility (EMC) – Part 2-2: Environment – Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems (Adopted CEI/IEC 61000-2-2:2002, second edition, 2002-03, with Canadian deviations) | Compatibilité électromagnétique (CEM) – Partie 2-2: Environnement – Niveaux de compatibilité pour les perturbations conduites à basse fréquence et la transmission des signaux sur les réseaux publics d’alimentation basse tension (norme CEI/IEC 61000-2-2:2002 adoptée, deuxième édition, 2002-03, avec exigences propres au Canada)
CDN $216.00
Electromagnetic compatibility (EMC) – Part 2-2: Environment – Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems (Adopted CEI/IEC 61000-2-2:2002, second edition, 2002-03, with Canadian deviations) | Compatibilité électromagnétique (CEM) – Partie 2-2: Environnement – Niveaux de compatibilité pour les perturbations conduites à basse fréquence et la transmission des signaux sur les réseaux publics d’alimentation basse tension (norme CEI/IEC 61000-2-2:2002 adoptée, deuxième édition, 2002-03, avec exigences propres au Canada)
Description
CSA Preface This is the second edition of CAN/CSA-C61000-2-2, Electromagnetic compatibility (EMC) – Part 2-2: Environment – Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems , which is an adoption, with Canadian deviations, of the identically titled CEI/IEC (Commission Électrotechnique Internationale/International Electrotechnical Commission) Standard 61000-2-2 (second edition, 2002-03). It supersedes the first edition published in 1997 as CAN/CSA-E1000-2-2 (adopted CEI/IEC 1000-2-2:1990). This Standard was reviewed for Canadian adoption by the CSA Subcommittee on Low-Frequency Electromagnetic Compatibility, under the jurisdiction of the Technical Committee on Electromagnetic Compatibility and the Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. A list of the members of the Technical Committee is available upon request. This Standard has been approved as a National Standard of Canada by the Standards Council of Canada. Scope and object This standard is concerned with conducted disturbances in the frequency range from 0 kHz to 9 kHz, with an extension up to 148,5 kHz specifically for mains signalling systems. It gives compatibility levels for public low voltage a.c. distribution systems having a nominal voltage up to 420 V, single-phase or 690 V, three-phase and a nominal frequency of 50 Hz or 60 Hz. The compatibility levels specified in this standard apply at the point of common coupling. At the power input terminals of equipment receiving its supply from the above systems the severity levels of the disturbances can, for the most part, be taken to be the same as the levels at the point of common coupling. In some situations this is not so, particularly in the case of a long line dedicated to the supply of a particular installation, or in the case of a disturbance generated or amplified within the installation of which the equipment forms a part. Compatibility levels are specified for electromagnetic disturbances of the types which can be expected in public low voltage power supply systems, for guidance in: – the limits to be set for disturbance emission into public power supply systems (including the planning levels defined in 3.1.5). – the immunity limits to be set by product committees and others for the equipment exposed to the conducted disturbances present in public power supply systems. The disturbance phenomena considered are: – voltage fluctuations and flicker; – harmonics up to and including order 50; – inter-harmonics up to the 50th harmonic; – voltage distortions at higher frequencies (above the 50th harmonic); – voltage dips and short supply interruptions; – voltage unbalance; – transient overvoltages; – power frequency variation; – d.c. components; – mains signalling. Most of these phenomena are described in IEC 61000-2-1. In cases where it is not yet possible to establish compatibility levels, some information is provided. ——————————————————————————————————————————– Préface CSA Ce document constitue la deuxième édition de la CAN/CSA-C61000-2-2, Compatibilité électromagnétique (CEM) – Partie 2-2 : Environnement – Niveaux de compatibilité pour les perturbations conduites à basse fréquence et la transmission des signaux sur les réseaux publics d’alimentation basse tension . Il s’agit de l’adoption, avec exigences propres au Canada, de la norme CEI/IEC (Commission Électrotechnique Internationale/International Electrotechnical Commission) 61000-2-2 (deuxième édition, 2002-03), qui porte le même titre. Cette norme remplace la première édition publiée en 1997 qui portait la désignation CAN/CSA-E1000-2-2 (norme CEI/IEC 1000-2-2:1990 adoptée). Cette norme a été révisée en vue de son adoption pour le Canada par le Sous-comité CSA sur la compatibilité électromagnétique à basse fréquence, sous l’autorité du Comité technique sur la compatibilité électromagnétique et du Comité directeur stratégique sur le génie en matière d’énergie et la compatibilité électromagnétique, et a été approuvée par le Comité technique. On peut obtenir la liste des membres du Comité technique sur demande. Cette norme a été approuvée en tant que Norme nationale du Canada par le Conseil canadien des normes. Domaine d’application et objet La présente norme est relative aux perturbations conduites dans le domaine de fréquences de 0 kHz à 9 kHz, avec une extension jusqu’à 148,5 kHz pour les systèmes de transmission de signaux sur le réseau. Elle fournit les valeurs numériques des niveaux de compatibilité pour les réseaux de distribution publics alternatifs basse tension, avec une tension nominale maximale de 420 V en monophasé, ou 690 V en triphasé, et une fréquence nominale de 50 Hz ou 60 Hz. Les niveaux de compatibilité spécifiés dans cette norme s’appliquent au point de couplage commun. Aux bornes d’un matériel alimenté par les réseaux décrits ci-dessus, la sévérité des perturbations peut, dans la plupart des cas, être considérée comme égale à celle au point de couplage commun. Il en va différemment dans certaines situations, notamment dans le cas d’une longue ligne dédiée à l’alimentation d’une installation définie, ou dans le cas d’une perturbation générée ou amplifiée dans l’installation dont l’équipement fait partie. Les niveaux de compatibilité sont donnés pour les perturbations électromagnétiques auxquelles on peut s’attendre sur les réseaux de distribution publics basse tension, dans le but d’aider à définir: – les limites devant être établies pour les émissions perturbatrices sur les réseaux publics de distribution d’énergie (comprenant les niveaux de planification tels qu’ils sont définis en 3.1.5); – les limites d’immunité devant être établies par les comités de produits ou autres concernant les équipements soumis aux perturbations conduites par les réseaux publics de distribution d’énergie. Les phénomènes perturbateurs considérés sont: – les fluctuations de tension et le flicker; – les harmoniques jusques et y compris le rang 50; – les inter-harmoniques jusqu’au rang 50; – les distorsions de tension aux fréquences supérieures (au-dessus du rang 50); – les creux de tension et les coupures brèves; – le déséquilibre de tension; – les surtensions transitoires; – les variations de fréquence fondamentale; – les composantes continues; – les systèmes de transmission de signaux sur le réseau. La plupart des ces phénomènes sont décrits dans la CEI 61000-2-1. Au cas où il n’est pas possible maintenant d’établir des niveaux de compatibilité, quelques informations sont fournies.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
89
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
CSA Preface This is the second edition of CAN/CSA-C61000-2-2, Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems , which is an adoption, with Canadian deviations, of the identically titled CEI/IEC (Commission Électrotechnique Internationale/International Electrotechnical Commission) Standard 61000-2-2 (second edition, 2002-03). It supersedes the first edition published in 1997 as CAN/CSA-E1000-2-2 (adopted CEI/IEC 1000-2-2:1990). This Standard was reviewed for Canadian adoption by the CSA Subcommittee on Low-Frequency Electromagnetic Compatibility, under the jurisdiction of the Technical Committee on Electromagnetic Compatibility and the Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. A list of the members of the Technical Committee is available upon request. This Standard has been approved as a National Standard of Canada by the Standards Council of Canada. Scope and object This standard is concerned with conducted disturbances in the frequency range from 0 kHz to 9 kHz, with an extension up to 148,5 kHz specifically for mains signalling systems. It gives compatibility levels for public low voltage a.c. distribution systems having a nominal voltage up to 420 V, single-phase or 690 V, three-phase and a nominal frequency of 50 Hz or 60 Hz. The compatibility levels specified in this standard apply at the point of common coupling. At the power input terminals of equipment receiving its supply from the above systems the severity levels of the disturbances can, for the most part, be taken to be the same as the levels at the point of common coupling. In some situations this is not so, particularly in the case of a long line dedicated to the supply of a particular installation, or in the case of a disturbance generated or amplified within the installation of which the equipment forms a part. Compatibility levels are specified for electromagnetic disturbances of the types which can be expected in public low voltage power supply systems, for guidance in: - the limits to be set for disturbance emission into public power supply systems (including the planning levels defined in 3.1.5). - the immunity limits to be set by product committees and others for the equipment exposed to the conducted disturbances present in public power supply systems. The disturbance phenomena considered are: - voltage fluctuations and flicker; - harmonics up to and including order 50; - inter-harmonics up to the 50th harmonic; - voltage distortions at higher frequencies (above the 50th harmonic); - voltage dips and short supply interruptions; - voltage unbalance; - transient overvoltages; - power frequency variation; - d.c. components; - mains signalling. Most of these phenomena are described in IEC 61000-2-1. In cases where it is not yet possible to establish compatibility levels, some information is provided. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la deuxième édition de la CAN/CSA-C61000-2-2, Compatibilité électromagnétique (CEM) - Partie 2-2 : Environnement - Niveaux de compatibilité pour les perturbations conduites à basse fréquence et la transmission des signaux sur les réseaux publics d'alimentation basse tension . Il s'agit de l'adoption, avec exigences propres au Canada, de la norme CEI/IEC (Commission Électrotechnique Internationale/International Electrotechnical Commission) 61000-2-2 (deuxième édition, 2002-03), qui porte le même titre. Cette norme remplace la première édition publiée en 1997 qui portait la désignation CAN/CSA-E1000-2-2 (norme CEI/IEC 1000-2-2:1990 adoptée). Cette norme a été révisée en vue de son adoption pour le Canada par le Sous-comité CSA sur la compatibilité électromagnétique à basse fréquence, sous l’autorité du Comité technique sur la compatibilité électromagnétique et du Comité directeur stratégique sur le génie en matière d’énergie et la compatibilité électromagnétique, et a été approuvée par le Comité technique. On peut obtenir la liste des membres du Comité technique sur demande. Cette norme a été approuvée en tant que Norme nationale du Canada par le Conseil canadien des normes. Domaine d'application et objet La présente norme est relative aux perturbations conduites dans le domaine de fréquences de 0 kHz à 9 kHz, avec une extension jusqu'à 148,5 kHz pour les systèmes de transmission de signaux sur le réseau. Elle fournit les valeurs numériques des niveaux de compatibilité pour les réseaux de distribution publics alternatifs basse tension, avec une tension nominale maximale de 420 V en monophasé, ou 690 V en triphasé, et une fréquence nominale de 50 Hz ou 60 Hz. Les niveaux de compatibilité spécifiés dans cette norme s'appliquent au point de couplage commun. Aux bornes d'un matériel alimenté par les réseaux décrits ci-dessus, la sévérité des perturbations peut, dans la plupart des cas, être considérée comme égale à celle au point de couplage commun. Il en va différemment dans certaines situations, notamment dans le cas d'une longue ligne dédiée à l'alimentation d'une installation définie, ou dans le cas d'une perturbation générée ou amplifiée dans l'installation dont l'équipement fait partie. Les niveaux de compatibilité sont donnés pour les perturbations électromagnétiques auxquelles on peut s'attendre sur les réseaux de distribution publics basse tension, dans le but d'aider à définir: - les limites devant être établies pour les émissions perturbatrices sur les réseaux publics de distribution d'énergie (comprenant les niveaux de planification tels qu'ils sont définis en 3.1.5); - les limites d'immunité devant être établies par les comités de produits ou autres concernant les équipements soumis aux perturbations conduites par les réseaux publics de distribution d'énergie. Les phénomènes perturbateurs considérés sont: - les fluctuations de tension et le flicker; - les harmoniques jusques et y compris le rang 50; - les inter-harmoniques jusqu'au rang 50; - les distorsions de tension aux fréquences supérieures (au-dessus du rang 50); - les creux de tension et les coupures brèves; - le déséquilibre de tension; - les surtensions transitoires; - les variations de fréquence fondamentale; - les composantes continues; - les systèmes de transmission de signaux sur le réseau. La plupart des ces phénomènes sont décrits dans la CEI 61000-2-1. Au cas où il n'est pas possible maintenant d'établir des niveaux de compatibilité, quelques informations sont fournies.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA E61558-2-5:25 – Safety of transformers, reactors, power supply units and combinations thereof — Part 2-5: Particular requirements and tests for transformers for shavers, power supply units for shavers and shaver supply units (Adopted IEC 61558-2-5:2024, third edition, 2024-08, with Canadian deviations) | Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et combinaisons de ces éléments — Partie 2-5 : Exigences particulières et essais pour les transformateurs pour rasoirs, les blocs d’alimentation incorporant un transformateur pour rasoir et les blocs d’alimentation pour rasoirs (norme IEC 61558-2-5:2024 adoptée, troisième édition, 2024-08, avec exigences propres au Canada)
CDN $299.00 Add to cart -

IEEE 844.4-2019/CSA C293.4:19 (R2024) – Impedance heating of pipelines and equipment—Application guide for design, installation, testing, commissioning, and maintenance
CDN $174.00 Add to cart -

CSA E61951-1:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 1: Nickel-cadmium (Adopted IEC 61951:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 1 : Nickel-cadmium (norme IEC 61951-1:2017 adoptée, quatrième édition, 2017-03), avec exigences propres au Canada)
CDN $527.00 Add to cart -

CSA E61347-2-3:23 – Lamp control gear — Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps (Adopted IEC 61347-2-3:2011, edition 2:2011 consolidated with amendment 1:2016, with Canadian deviations) | Appareillages de lampes — Partie 2-3 : Exigences particulières pour les appareillages électroniques alimentés en courant alternatif et/ou en courant continu pour lampes fluorescentes (norme IEC 61347-2-3:2011 adoptée, édition 2:2011 consolidée par l’amendement 1:2016, avec exigences propres au Canada)
CDN $620.00 Add to cart