Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CAN1-6.4-M79 (R2021)

CAN1-6.4-M79 (R2021) – Automatic gas ignition systems and components

CDN $273.00

Automatic gas ignition systems and components

SKU: 2412701 Categories: ,

Description

Scope 1.1.1 This Standard applies to newly produced automatic gas ignition systems (see Part III, Definitions) and components thereof other than types utilizing low, extra low, or high voltages, constructed entirely of new, unused parts and materials. An automatic gas ignition system shall perform the following functions: a) Ignite the gas at the main burner(s), b) Prove the presence of either the ignition means, the main burner flame, or both; and c) Automatically act to shut off the gas supply to the main burner(s), or to the pilot burner(s) and the main burner(s), when the supervised flame or ignition means is not proved. Components submitted for examination under this standard shall perform one or more of the above functions. 1.1.2 This Standard covers automatic gas ignition systems and components thereof intended primarily for use with gas appliances having inputs of 400 000 Btuh (117.23 kW) or less per individual combustion chamber. 1.1.3 This Standard applies to automatic gas ignition systems and components thereof for use with one or more of the following gases: a) Natural b) Propane 1.1.4 Compliance of an automatic gas ignition system or component thereof with this standard does not imply that such a system or component of such a system is acceptable for use on gas appliances without supplemental tests with the device(s) applied to the particular appliance design. 1.1.5 Each component of an automatic gas ignition system shall be capable of operation throughout a temperature range of 32°F (0°C) to 125°F (52°C) unless either higher, lower, or both higher and lower temperatures are specified by the manufacturer. At the option of the manufacturer, the operating temperature range may be increased above 125°F (52°C) in increments of 25°F (14°C) and may be reduced below 32°F (0°C) to either -20°F (- 29°C) or -40°F (-40°C). 1.1.6 The tests specified herein are to verify performance within the manufacturer’s specified maximum and minimum timings where applicable. a) Flame-establishing period b) Flame failure response time The above terms are defined in Part III, Definitions. 1.1.7 For low, extra low, and high voltage automatic gas ignition systems and components thereof, the current standard CSA C22.2 No. 24 TEMPERATURE INDICATING AND REGULATING EQUIPMENT applies.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

22

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Scope 1.1.1 This Standard applies to newly produced automatic gas ignition systems (see Part III, Definitions) and components thereof other than types utilizing low, extra low, or high voltages, constructed entirely of new, unused parts and materials. An automatic gas ignition system shall perform the following functions: a) Ignite the gas at the main burner(s), b) Prove the presence of either the ignition means, the main burner flame, or both; and c) Automatically act to shut off the gas supply to the main burner(s), or to the pilot burner(s) and the main burner(s), when the supervised flame or ignition means is not proved. Components submitted for examination under this standard shall perform one or more of the above functions. 1.1.2 This Standard covers automatic gas ignition systems and components thereof intended primarily for use with gas appliances having inputs of 400 000 Btuh (117.23 kW) or less per individual combustion chamber. 1.1.3 This Standard applies to automatic gas ignition systems and components thereof for use with one or more of the following gases: a) Natural b) Propane 1.1.4 Compliance of an automatic gas ignition system or component thereof with this standard does not imply that such a system or component of such a system is acceptable for use on gas appliances without supplemental tests with the device(s) applied to the particular appliance design. 1.1.5 Each component of an automatic gas ignition system shall be capable of operation throughout a temperature range of 32°F (0°C) to 125°F (52°C) unless either higher, lower, or both higher and lower temperatures are specified by the manufacturer. At the option of the manufacturer, the operating temperature range may be increased above 125°F (52°C) in increments of 25°F (14°C) and may be reduced below 32°F (0°C) to either -20°F (- 29°C) or -40°F (-40°C). 1.1.6 The tests specified herein are to verify performance within the manufacturer's specified maximum and minimum timings where applicable. a) Flame-establishing period b) Flame failure response time The above terms are defined in Part III, Definitions. 1.1.7 For low, extra low, and high voltage automatic gas ignition systems and components thereof, the current standard CSA C22.2 No. 24 TEMPERATURE INDICATING AND REGULATING EQUIPMENT applies.

Previous Editions

Can’t find what you are looking for?

Please contact us at: