CGA 3.4-1973 (R2025)
CGA 3.4-1973 (R2025) – Industrial and Commercial Gas-Fired Conversion Burners
CDN $273.00
Industrial and Commercial Gas-Fired Conversion Burners
Description
Scope 1.1.1 These requirements apply to natural and propane gas-fired conversion burners designed and constructed primarily for the purpose of converting heating and process equipment from the use of other fuels to gas firing and/or firing new heating or process equipment. 1.1.2 Section 2, Part “A” of these requirements apply to conversion burners having a maximum input rating within the range of over 400,000 BTUH, up to and including 10,000,000 BTUH. A con version burner series extending below 400,000 BTUH input may be investigated according to the intent of these requirements. 1.1.3 Section 2, Part “B” of the standard includes requirements additional to those of Part “A” and apply to conversion burners having manufacturer’s maximum input ratings in excess of 10,000,000 BTUH and up to and including 50,000,000 BTUH. 1.1.4 These requirements apply to atmospheric, fan assist and forced draft type conversion burners. 1.1.5 A conversion burner which complies with these requirements shall not be acceptable if it has features which impair the results contemplated by the requirements.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
56
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Scope 1.1.1 These requirements apply to natural and propane gas-fired conversion burners designed and constructed primarily for the purpose of converting heating and process equipment from the use of other fuels to gas firing and/or firing new heating or process equipment. 1.1.2 Section 2, Part "A" of these requirements apply to conversion burners having a maximum input rating within the range of over 400,000 BTUH, up to and including 10,000,000 BTUH. A con version burner series extending below 400,000 BTUH input may be investigated according to the intent of these requirements. 1.1.3 Section 2, Part "B" of the standard includes requirements additional to those of Part "A" and apply to conversion burners having manufacturer's maximum input ratings in excess of 10,000,000 BTUH and up to and including 50,000,000 BTUH. 1.1.4 These requirements apply to atmospheric, fan assist and forced draft type conversion burners. 1.1.5 A conversion burner which complies with these requirements shall not be acceptable if it has features which impair the results contemplated by the requirements.