Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CGA 9.2-M88 (R2009)

CGA 9.2-M88 (R2009) – CGA 9.2-M88 (R2009) – Manually Operated Shut-Off Valves for Gas Piping Systems

CDN $273.00

CGA 9.2-M88 (R2009) – Manually Operated Shut-Off Valves for Gas Piping Systems

SKU: 2413234 Categories: ,

Description

Scope 1.1.1 This standard applies to newly produced manually operated shut-off valves for gas piping systems and constructed of entir ely new, unused parts and materials which: (a) are intended for use downstream of the distributors meter or regulator, for operation at a maximum pressure of 1/2 psig (3.4 kPa), (b) are capable of operation at ambient temperatures between 32°F (0°C) and 125°F (52°C) and in addition are also capable of operation at a higher temperature, a lower temperature or both when so specified by the manufacturer, (c) are valves substantially of the plug and body, or rotating disc t ype, and valves of other types which will provide equivalent performance. 1.1.2 Constructional provisions for spring loaded type manually operated gas shut-off valves are covered in Part 2 “Spring Loaded Type Valves-Construction.” Performance provisions for spring loaded type manually operated gas shut-off valves are covered in Part 3 “Spring Loaded Type Valves-Performance.” Constructional provisions for solid bottom type manually operated gas shut-off valves are covered in Part 4 “Solid Bottom Type Valves-Construction.” Performance provisions for solid bottom type manually operated gas shut-off valves are covered in Part 5 “Solid Bottom Type Valves-Performance. 1.1.3 Room temperature, when specified in this standard, shall be considered at 77 ± 10°F (25 ± 5.6°C). 1.1.4 This standard contains SI (Metric) equivalents to the y ard/pound quantities, the purpose being to allow the standard to be used in SI (Metric) units. If a value for a measurement as given in this standard is followed by an equivalent value in other u nits, the first stated is to be regarded as the requirement. The given equivalent may be approximate. If a value for a measurement and an equivalent value in other units are both specified as a quoted marking requirement, the first stated unit, or both units shall be provided.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

32

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Scope 1.1.1 This standard applies to newly produced manually operated shut-off valves for gas piping systems and constructed of entir ely new, unused parts and materials which: (a) are intended for use downstream of the distributors meter or regulator, for operation at a maximum pressure of 1/2 psig (3.4 kPa), (b) are capable of operation at ambient temperatures between 32°F (0°C) and 125°F (52°C) and in addition are also capable of operation at a higher temperature, a lower temperature or both when so specified by the manufacturer, (c) are valves substantially of the plug and body, or rotating disc t ype, and valves of other types which will provide equivalent performance. 1.1.2 Constructional provisions for spring loaded type manually operated gas shut-off valves are covered in Part 2 "Spring Loaded Type Valves-Construction." Performance provisions for spring loaded type manually operated gas shut-off valves are covered in Part 3 "Spring Loaded Type Valves-Performance." Constructional provisions for solid bottom type manually operated gas shut-off valves are covered in Part 4 "Solid Bottom Type Valves-Construction." Performance provisions for solid bottom type manually operated gas shut-off valves are covered in Part 5 "Solid Bottom Type Valves-Performance. 1.1.3 Room temperature, when specified in this standard, shall be considered at 77 ± 10°F (25 ± 5.6°C). 1.1.4 This standard contains SI (Metric) equivalents to the y ard/pound quantities, the purpose being to allow the standard to be used in SI (Metric) units. If a value for a measurement as given in this standard is followed by an equivalent value in other u nits, the first stated is to be regarded as the requirement. The given equivalent may be approximate. If a value for a measurement and an equivalent value in other units are both specified as a quoted marking requirement, the first stated unit, or both units shall be provided.