Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA 9.4:21 (R2026)

CSA 9.4:21 (R2026) – Standard for manually operated metallic gas valves for use on piping systems up to 5 psig

CDN $480.00

Standard for manually operated metallic gas valves for use on piping systems up to 5 psig

SKU: 2428818 Categories: ,

Description

Preface This is the first edition of CSA 9.4, Standard for manually operated metallic gas valves for use on piping systems up to 5 psig and was developed from the certification requirement CSA CR91-002. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Joint Subcommittee on Standards on Manual Valves, under the jurisdiction of the Technical Committee on Gas Appliances and Related Accessories, and the Strategic Steering Committee on Fuels and Appliances, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to newly produced manually operated metallic gas shut-off valves, hereinafter referred to as valves, constructed entirely of new, unused parts and materials that a) are for indoor/outdoor installation; b) are for use in the gas piping between the outlet of the gas distributor’s meter and the inlet connection of the pressure regulator installed upstream of the manual valve in the gas piping to each appliance; c) are capable of operation at ambient temperatures between 32 to 125 °F (0 to 52 °C) if intended for indoor use only, or temperatures between –40 to 180 °F (–40 to 82 °C) if intended for indoor/ outdoor use; d) are to be rated for either 2 psig (14 kPa) or 5 psig (35 kPa); and e) include sizes 1/4 through 4 in NPS and tubing sizes 1/4 in through 1 in O.D. 1.2 A valve covered under this Standard is for use with natural gas, manufactured gas, or propane gas. 1.3 This Standard sets forth the minimum capabilities, characteristics, and properties that a valve must possess, at the time of manufacture, in order to be considered suitable for use in an indoor/outdoor gas piping system. Details of design and manufacture, other than those stated in this Standard, including such design and production tests that will produce a valve that will have the required capabilities to meet the Standard, remain the responsibility of the manufacturer. 1.4 All references to pressure throughout this Standard are to be considered gauge pressures, unless otherwise specified. 1.5 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

31

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the first edition of CSA 9.4, Standard for manually operated metallic gas valves for use on piping systems up to 5 psig and was developed from the certification requirement CSA CR91-002. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Joint Subcommittee on Standards on Manual Valves, under the jurisdiction of the Technical Committee on Gas Appliances and Related Accessories, and the Strategic Steering Committee on Fuels and Appliances, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to newly produced manually operated metallic gas shut-off valves, hereinafter referred to as valves, constructed entirely of new, unused parts and materials that a) are for indoor/outdoor installation; b) are for use in the gas piping between the outlet of the gas distributor's meter and the inlet connection of the pressure regulator installed upstream of the manual valve in the gas piping to each appliance; c) are capable of operation at ambient temperatures between 32 to 125 °F (0 to 52 °C) if intended for indoor use only, or temperatures between –40 to 180 °F (–40 to 82 °C) if intended for indoor/ outdoor use; d) are to be rated for either 2 psig (14 kPa) or 5 psig (35 kPa); and e) include sizes 1/4 through 4 in NPS and tubing sizes 1/4 in through 1 in O.D. 1.2 A valve covered under this Standard is for use with natural gas, manufactured gas, or propane gas. 1.3 This Standard sets forth the minimum capabilities, characteristics, and properties that a valve must possess, at the time of manufacture, in order to be considered suitable for use in an indoor/outdoor gas piping system. Details of design and manufacture, other than those stated in this Standard, including such design and production tests that will produce a valve that will have the required capabilities to meet the Standard, remain the responsibility of the manufacturer. 1.4 All references to pressure throughout this Standard are to be considered gauge pressures, unless otherwise specified. 1.5 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.