Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA/ANSI Z21.107:24

CSA/ANSI Z21.107:24 – Gas thermal shutoff devices

CDN $614.00

Gas thermal shutoff devices

SKU: 2431554 Categories: ,

Description

Preface This is the first edition of Z21.107, Gas thermal shutoff devices . The seed document for this Standard was CSA IR 5. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Z21/CSA Joint Technical Advisory Group on Manually Operated Gas Valves, under the jurisdiction of the Technical Committee on Gas Appliances and Related Accessories and the Strategic Steering Committee on Standards for Gas Appliances and Related Accessories, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. This Standard has been approved by the American National Standards Institute (ANSI) as an American National Standard. Scope 1.1 Application and material requirements for gas thermal shutoff devices This Standard applies to gas thermal shutoff devices constructed entirely of new unused parts and materials intended for use after the service meter or second stage regulator, hereinafter referred to as “devices”, ranging from 3/8 in (DN 10) up to 6 in (DN 150) nominal pipe size. 1.2 Automatic gas flow shutoff devices Devices covered by this Standard automatically shut off the gas flow when they reach a set temperature. This is a single use control. 1.3 Application of devices for use with natural or propane gas This Standard applies to devices for use with natural or propane gas, at pressures not to exceed 72 psi (496 kPa). 1.4 Ambient temperatures Unless otherwise specified, all tests specified herein are conducted at the ambient temperatures specified by the manufacturer as follows: a) at ambient temperatures of 32 °F (0 °C) and 158 °F (70 °C) if the manufacturer’s specified temperature range is from 32 °F (0 °C) to 158 °F (70 °C) and for indoor use only devices; or b) at ambient temperatures of −20 °F (−29 °C) and 158 °F (70 °C) if the manufacturer’s specified temperature range is from −20 °F (−29 °C) to 158 °F (70 °C); c) at ambient temperatures of −40 °F (−40 °C) and 158 °F (70 °C) if the manufacturer’s specified temperature range is from −40 °F (−40 °C) to 158 °F (70 °C). 1.5 Compliance of non-gas thermal shutoff device components with applicable standards Components performing functions other than those of a gas thermal shutoff device are to comply with applicable American National Standards or Canadian Standards. 1.6 Reference to pressure measurements All references to pressure throughout this Standard are to be considered gauge pressures, unless otherwise specified. 1.7 Terminology In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.8 Units of measure The values given in US customary units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

43

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the first edition of Z21.107, Gas thermal shutoff devices . The seed document for this Standard was CSA IR 5. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Z21/CSA Joint Technical Advisory Group on Manually Operated Gas Valves, under the jurisdiction of the Technical Committee on Gas Appliances and Related Accessories and the Strategic Steering Committee on Standards for Gas Appliances and Related Accessories, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. This Standard has been approved by the American National Standards Institute (ANSI) as an American National Standard. Scope 1.1 Application and material requirements for gas thermal shutoff devices This Standard applies to gas thermal shutoff devices constructed entirely of new unused parts and materials intended for use after the service meter or second stage regulator, hereinafter referred to as "devices", ranging from 3/8 in (DN 10) up to 6 in (DN 150) nominal pipe size. 1.2 Automatic gas flow shutoff devices Devices covered by this Standard automatically shut off the gas flow when they reach a set temperature. This is a single use control. 1.3 Application of devices for use with natural or propane gas This Standard applies to devices for use with natural or propane gas, at pressures not to exceed 72 psi (496 kPa). 1.4 Ambient temperatures Unless otherwise specified, all tests specified herein are conducted at the ambient temperatures specified by the manufacturer as follows: a) at ambient temperatures of 32 °F (0 °C) and 158 °F (70 °C) if the manufacturer’s specified temperature range is from 32 °F (0 °C) to 158 °F (70 °C) and for indoor use only devices; or b) at ambient temperatures of −20 °F (−29 °C) and 158 °F (70 °C) if the manufacturer’s specified temperature range is from −20 °F (−29 °C) to 158 °F (70 °C); c) at ambient temperatures of −40 °F (−40 °C) and 158 °F (70 °C) if the manufacturer’s specified temperature range is from −40 °F (−40 °C) to 158 °F (70 °C). 1.5 Compliance of non-gas thermal shutoff device components with applicable standards Components performing functions other than those of a gas thermal shutoff device are to comply with applicable American National Standards or Canadian Standards. 1.6 Reference to pressure measurements All references to pressure throughout this Standard are to be considered gauge pressures, unless otherwise specified. 1.7 Terminology In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.8 Units of measure The values given in US customary units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.

Previous Editions

Can’t find what you are looking for?

Please contact us at: