Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C22.10:26

CSA C22.10:26 – Construction Code, Chapter V, Electricity Canadian Electrical Code, Part I (twenty-fifth edition) with Québec Amendments

CDN $307.00

Construction Code, Chapter V, Electricity Canadian Electrical Code, Part I (twenty-fifth edition) with Québec Amendments

SKU: 2432452 Categories: ,

Description

Preface This twenty-fifth edition of the Canadian Electrical Code, Part I, was approved by the Committee on the Canadian Electrical Code, Part I, and by the Regulatory Authority Committee at their June 2020 meetings. This twenty-fifth edition supersedes the previous editions, published in 2018, 2015, 2012, 2009, 2006, 2002, 1998, 1994, 1990, 1986, 1982, 1978, 1975, 1972, 1969, 1966, 1962, 1958, 1953, 1947, 1939, 1935, 1930, and 1927. This edition contains important revisions to many Sections. Section 64 features a new Subsection governing installation of energy storage systems and Rules for functionally-grounded renewable energy systems. Several important changes appear in Section 26, including a new requirement for ground fault circuit interrupter protection for all 15 A and 20 A receptacles located outdoors within 2.5 m of grade. New requirements in support of climate change adaptation appear in several Sections of the Code. Section 22 now contains a new Subsection for farm buildings housing livestock, as well as revised Rules for equipment in Category 1 and 2 locations. Other significant revisions in this edition include the following: • redundant or out-of-date requirements, such as the Rules for open wiring, have been removed; • the definition for “Voltage — Low voltage” has been revised in Section 0; • clarification has been provided on impedance grounded system operation under fault condition in Section 10; • new requirements for electrical equipment installed near roof decking systems have been added in Section 12; • load calculations and equipment layout for recreational vehicle lots have been updated in Section 72; • Table 19 has been completely reorganized, simplified, and shortened; • Annexes A.1 and A.2 of Appendix A have been removed and are now hosted online; and • Appendix E has been deleted. Many of the changes in this edition were developed by cross-functional working groups. Their work is gratefully acknowledged. Scope This Code applies to all electrical work and electrical equipment operating or intended to operate at all voltages in electrical installations for buildings, structures, and premises, including factory-built relocatable and non-relocatable structures, and self-propelled marine vessels stationary for periods exceeding five months and connected to a shore supply of electricity continuously or from time to time, with the following exceptions: a) installations or equipment employed by an electric, communication, or community antenna distribution system utility in the exercise of its function as a utility, as recognized by the regulatory authority having jurisdiction, and located outdoors or in buildings or sections of buildings used for that purpose; b) equipment and facilities that are used in the operation of an electric railway and are supplied exclusively from circuits that supply the motive power; c) installations or equipment used for railway signalling and railway communication purposes, and located outdoors or in buildings or sections of buildings used exclusively for such installations; d) aircraft; and e) electrical systems in ships that are regulated under Transport Canada. For mines and quarry applications, see also CSA M421. This Code and any standards referenced in it do not make or imply any assurance or guarantee by the authority adopting this Code with respect to life expectancy, durability, or operating performance of equipment and materials so referenced.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

961

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This twenty-fifth edition of the Canadian Electrical Code, Part I, was approved by the Committee on the Canadian Electrical Code, Part I, and by the Regulatory Authority Committee at their June 2020 meetings. This twenty-fifth edition supersedes the previous editions, published in 2018, 2015, 2012, 2009, 2006, 2002, 1998, 1994, 1990, 1986, 1982, 1978, 1975, 1972, 1969, 1966, 1962, 1958, 1953, 1947, 1939, 1935, 1930, and 1927. This edition contains important revisions to many Sections. Section 64 features a new Subsection governing installation of energy storage systems and Rules for functionally-grounded renewable energy systems. Several important changes appear in Section 26, including a new requirement for ground fault circuit interrupter protection for all 15 A and 20 A receptacles located outdoors within 2.5 m of grade. New requirements in support of climate change adaptation appear in several Sections of the Code. Section 22 now contains a new Subsection for farm buildings housing livestock, as well as revised Rules for equipment in Category 1 and 2 locations. Other significant revisions in this edition include the following: • redundant or out-of-date requirements, such as the Rules for open wiring, have been removed; • the definition for "Voltage — Low voltage" has been revised in Section 0; • clarification has been provided on impedance grounded system operation under fault condition in Section 10; • new requirements for electrical equipment installed near roof decking systems have been added in Section 12; • load calculations and equipment layout for recreational vehicle lots have been updated in Section 72; • Table 19 has been completely reorganized, simplified, and shortened; • Annexes A.1 and A.2 of Appendix A have been removed and are now hosted online; and • Appendix E has been deleted. Many of the changes in this edition were developed by cross-functional working groups. Their work is gratefully acknowledged. Scope This Code applies to all electrical work and electrical equipment operating or intended to operate at all voltages in electrical installations for buildings, structures, and premises, including factory-built relocatable and non-relocatable structures, and self-propelled marine vessels stationary for periods exceeding five months and connected to a shore supply of electricity continuously or from time to time, with the following exceptions: a) installations or equipment employed by an electric, communication, or community antenna distribution system utility in the exercise of its function as a utility, as recognized by the regulatory authority having jurisdiction, and located outdoors or in buildings or sections of buildings used for that purpose; b) equipment and facilities that are used in the operation of an electric railway and are supplied exclusively from circuits that supply the motive power; c) installations or equipment used for railway signalling and railway communication purposes, and located outdoors or in buildings or sections of buildings used exclusively for such installations; d) aircraft; and e) electrical systems in ships that are regulated under Transport Canada. For mines and quarry applications, see also CSA M421. This Code and any standards referenced in it do not make or imply any assurance or guarantee by the authority adopting this Code with respect to life expectancy, durability, or operating performance of equipment and materials so referenced.