Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C22.2 NO. 115:25

CSA C22.2 NO. 115:25 – Meter-mounting devices

CDN $197.00

Meter-mounting devices

SKU: 2432017 Categories: ,

Description

Preface This is the eighth edition of CSA C22.2 No. 115, Meter-mounting devices , one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. It supersedes the previous editions published in 2020, 2014, 1989, 1983, 1971, 1967, and 1963. Changes to this edition include a) additions and revisions to definitions (Clause 3); b) revisions to allowance in distance from top of socket to top of jaw; c) marking requirements for neutral bonding kits; d) revisions to meter jaw safety guard requirements; e) additions and revisions to marking requirements; f) revisions to weather and humidity test requirements; and g) revisions to Table 7. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Meter-Mounting Devices, under the jurisdiction of the Technical Committee on Industrial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to indoor or outdoor meter-mounting devices, and combination meter-mounting devices. These devices can be single position or multiple positions, either as complete self-contained devices or provided as part of service equipment for use in nonhazardous locations, and are intended to be used in accordance with Canadian Electrical Code, Part I (“CE Code, Part I”). 1.2 This Standard applies to devices for use with watt-hour meters, demand meters, time switches, current transformers, test switches, instruments, and similar devices rated at 320 A or less per meter-mounting device, 600 V or less (300 V or less for combination meter-mounting device), single or polyphase, and multiple-position meter-mounting devices with an overall current rating of 600 A or less (320 A maximum per position). 1.3 This Standard applies to subfeed meter-mounting devices that have provision for the main load terminations and for one subfeed termination. 1.4 This Standard applies to the meter-mounting device portion when supplied as a part of service or other equipment where applicable. 1.5 Non-combination meter-mounting devices, as applied to by this Standard, are not intended to be used as load-making or load-breaking devices. 1.6 This Standard applies to transformer-rated meter-mounting devices that consist of current transformers, meter-sockets, and optional test switches, mounted in the same enclosure rated 600 A or less and 600 V (nominal) or less. 1.7 This Standard does not apply to products under the scope of CSA C22.2 No. 229. 1.8 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

74

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the eighth edition of CSA C22.2 No. 115, Meter-mounting devices , one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. It supersedes the previous editions published in 2020, 2014, 1989, 1983, 1971, 1967, and 1963. Changes to this edition include a) additions and revisions to definitions (Clause 3); b) revisions to allowance in distance from top of socket to top of jaw; c) marking requirements for neutral bonding kits; d) revisions to meter jaw safety guard requirements; e) additions and revisions to marking requirements; f) revisions to weather and humidity test requirements; and g) revisions to Table 7. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Meter-Mounting Devices, under the jurisdiction of the Technical Committee on Industrial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to indoor or outdoor meter-mounting devices, and combination meter-mounting devices. These devices can be single position or multiple positions, either as complete self-contained devices or provided as part of service equipment for use in nonhazardous locations, and are intended to be used in accordance with Canadian Electrical Code, Part I ("CE Code, Part I"). 1.2 This Standard applies to devices for use with watt-hour meters, demand meters, time switches, current transformers, test switches, instruments, and similar devices rated at 320 A or less per meter-mounting device, 600 V or less (300 V or less for combination meter-mounting device), single or polyphase, and multiple-position meter-mounting devices with an overall current rating of 600 A or less (320 A maximum per position). 1.3 This Standard applies to subfeed meter-mounting devices that have provision for the main load terminations and for one subfeed termination. 1.4 This Standard applies to the meter-mounting device portion when supplied as a part of service or other equipment where applicable. 1.5 Non-combination meter-mounting devices, as applied to by this Standard, are not intended to be used as load-making or load-breaking devices. 1.6 This Standard applies to transformer-rated meter-mounting devices that consist of current transformers, meter-sockets, and optional test switches, mounted in the same enclosure rated 600 A or less and 600 V (nominal) or less. 1.7 This Standard does not apply to products under the scope of CSA C22.2 No. 229. 1.8 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.