Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C22.2 NO. 166:15 (R2025)

CSA C22.2 NO. 166:15 (R2025) – Stage and studio luminaires

CDN $189.00

Stage and studio luminaires

SKU: 2423628 Categories: ,

Description

Preface This is the second edition of CSA C22.2 No. 166, Stage and studio luminaires , one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. This edition supersedes the previous edition, published in 1983. This Standard also replaces the following Technical Information Letter (TIL), for products covered in this Standard: TIL No. B-42A, “Interim Certification Requirements for Guarding of Stage and Studio Non-Lensed Luminaires Using Tungsten-Halogen Lamps”.  For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0, General requirements – Canadian Electrical Code, Part II.  Scope 1.1 This Standard applies to portable and stationary stage and studio luminaires, integrated controls, and power supplies of all types suitable for use in dry, damp, or wet locations, intended for use in nonhazardous locations and for connection to a supply circuit of 600 V or less between conductors, and designed to be installed and used in accordance with CSA C22.1, Canadian Electrical Code, Part I (CE Code, Part I).  1.2 This Standard does not apply to external power supplies for discharge lamps.  1.3 The equipment covered in this Standard is not intended for household use.  Note: See Table 7.1, Item 8, for the corresponding marking.  1.4 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard.  Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.  Notes to tables and figures are considered part of the table or figure and may be written as requirements.  Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.  1.5 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

57

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the second edition of CSA C22.2 No. 166, Stage and studio luminaires , one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. This edition supersedes the previous edition, published in 1983. This Standard also replaces the following Technical Information Letter (TIL), for products covered in this Standard: TIL No. B-42A, "Interim Certification Requirements for Guarding of Stage and Studio Non-Lensed Luminaires Using Tungsten-Halogen Lamps".  For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0, General requirements - Canadian Electrical Code, Part II.  Scope 1.1 This Standard applies to portable and stationary stage and studio luminaires, integrated controls, and power supplies of all types suitable for use in dry, damp, or wet locations, intended for use in nonhazardous locations and for connection to a supply circuit of 600 V or less between conductors, and designed to be installed and used in accordance with CSA C22.1, Canadian Electrical Code, Part I (CE Code, Part I).  1.2 This Standard does not apply to external power supplies for discharge lamps.  1.3 The equipment covered in this Standard is not intended for household use.  Note: See Table 7.1, Item 8, for the corresponding marking.  1.4 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.  Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.  Notes to tables and figures are considered part of the table or figure and may be written as requirements.  Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.  1.5 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.

Previous Editions

Can’t find what you are looking for?

Please contact us at: