
CSA C22.2 NO. 166:15 (R2025)
CSA C22.2 NO. 166:15 (R2025) – Stage and studio luminaires
CDN $189.00
Stage and studio luminaires
Description
Preface This is the second edition of CSA C22.2 No. 166, Stage and studio luminaires , one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. This edition supersedes the previous edition, published in 1983. This Standard also replaces the following Technical Information Letter (TIL), for products covered in this Standard: TIL No. B-42A, “Interim Certification Requirements for Guarding of Stage and Studio Non-Lensed Luminaires Using Tungsten-Halogen Lamps”. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0, General requirements – Canadian Electrical Code, Part II. Scope 1.1 This Standard applies to portable and stationary stage and studio luminaires, integrated controls, and power supplies of all types suitable for use in dry, damp, or wet locations, intended for use in nonhazardous locations and for connection to a supply circuit of 600 V or less between conductors, and designed to be installed and used in accordance with CSA C22.1, Canadian Electrical Code, Part I (CE Code, Part I). 1.2 This Standard does not apply to external power supplies for discharge lamps. 1.3 The equipment covered in this Standard is not intended for household use. Note: See Table 7.1, Item 8, for the corresponding marking. 1.4 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application. 1.5 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
57
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the second edition of CSA C22.2 No. 166, Stage and studio luminaires , one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. This edition supersedes the previous edition, published in 1983. This Standard also replaces the following Technical Information Letter (TIL), for products covered in this Standard: TIL No. B-42A, "Interim Certification Requirements for Guarding of Stage and Studio Non-Lensed Luminaires Using Tungsten-Halogen Lamps". For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0, General requirements - Canadian Electrical Code, Part II. Scope 1.1 This Standard applies to portable and stationary stage and studio luminaires, integrated controls, and power supplies of all types suitable for use in dry, damp, or wet locations, intended for use in nonhazardous locations and for connection to a supply circuit of 600 V or less between conductors, and designed to be installed and used in accordance with CSA C22.1, Canadian Electrical Code, Part I (CE Code, Part I). 1.2 This Standard does not apply to external power supplies for discharge lamps. 1.3 The equipment covered in this Standard is not intended for household use. Note: See Table 7.1, Item 8, for the corresponding marking. 1.4 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application. 1.5 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA E62660-1:21 (R2026) – Secondary lithium-ion cells for the propulsion of electric road vehicles – Part 1: Performance testing (Adopted IEC 62660-1:2018, second edition, 2018-12, with Canadian deviations) | Éléments d’accumulateurs lithium-ion pour la propulsion des véhicules routiers électriques – Partie 1 : Essais de performance (norme IEC 62660-1:2018 adoptée, deuxième édition, 2018-12, avec exigences propres au Canada)
CDN $436.00 Add to cart -

CSA SPE-1000:25 – Model Code for the field evaluation of electrical equipment
CDN $378.00 Add to cart -

CSA E61558-2-13:25 – Safety of transformers, reactors, power supply units and combinations thereof — Part 2-13: Particular requirements and tests for auto-transformers and power supply units incorporating auto-transformers for general applications (Adopted IEC 61558-2-13:2022, third edition, 2022-10, with Canadian deviations) | Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et combinaisons de ces éléments — Partie 2-13 : Exigences particulières et essais pour les autotransformateurs et les blocs d’alimentation qui incorporent des autotransformateurs pour applications d’ordre général (norme IEC 61558-2-13:2022 adoptée, troisième édition, 2022-10, avec exigences propres au Canada)
CDN $205.00 Add to cart -

IEEE 844.1-2017/CSA C22.2 NO. 293.1:17 (R2022) – Skin effect trace heating of pipelines, vessels, equipment, and structures—General, testing, marking, and documentation requirements
CDN $158.00 Add to cart







